Owner`s manual
25700-1-0809 Page 31
DIRECT VENT INSTALLATION INSTRUCTIONS
DIRECT VENT
FLUE KIT
FLUE CENTER
12” (30.5 cm)
MINIMUM
EXTERIOR GRADE
GAS SUPPLY
SURROUND
MANTEL
Figure 47
HorizontalVenting
Note: Do not glue intake or exhaust pipes to Direct Vent Adaptor for serviceability.
PVVK-24HandPVVK-48HVentKitavailablefromEmpireComfortSystems,Inc.
EXTERIOR GRADE
FLUE CENTER
12”
(30.5cm)
MIN.
Figure 48
Minimum Exterior Grade Dimension
Installation on Rugs and Tile
If this appliance is to be installed directly on carpeting, tile, or other
combustible material, other than wood ooring, the appliance shall
be installed on a metal or wood panel extending the full width and
depth of the appliance.
The base referred to above does not mean the re-proof base as
used on wood stoves. The protection is primarily for rugs that may
be extremely thick and light-color tile that can discolor.
EXTERIOR GRADE
FLUE CENTER
1 1/4”
(3.2cm)
MIN.
12”
(30.5cm)MIN.
FLOOR PROTECTION
Figure 49
Minimum Exterior Grade Dimension - Existing Fireplace Installation