Specifications

27297-5-0511 Page 7
Bay Window Mantis Models B(F,I,P)28(B,C,G)M(N,P)
Input BTU/HR (KW/H) 19,000 Rear - 9,000 Front
Height 25-1/4”
Width 28”
Depth 17-5/8”
Gas Inlet (Pipe) 3/8” Flair
Electrical - The unit comes equipped with a 5 foot (1.5 m) 3
pronged cord, for connection to an approved
115 VAC, 60 Hz , 5A (maximum) wall receptacle.
Vent Pipe: - 1-1/2 inch diameter schedule 40 PVC pipe, 40
feet maximum equivalent length.
SPECIFICATIONS & ACCESSORIES
Fireplace Mantis Models F(F,I,W)28BM(N,P)
Input BTU/HR (KW/H) 15,000 Rear - 13,000 Front
Height 24-9/16”
Width 28”
Depth 17-3/16”
Gas Inlet (Pipe) 3/8” Flair
Electrical - The unit comes equipped with a 5 foot (1.5 m)
3 pronged cord, for connection to an approved
115 VAC, 60 Hz, 5A (maximum) wall receptacle.
Vent Pipe: - 1-1/2 inch diameter schedule 40 PVC pipe, 40
feet maximum equivalent length.
ACCESSORIES
Common
Part Number Description
FRBTC Battery Operated Remote with Thermostat
FRBTP Battery Operated Remote with Programmable Thermostat
PVCA Colinear Adapter
PVCT Colinear Transition Kit
PVVK-CFA Flex Vent Kit
PVVK-SH Single Flue Horizontal Vent Kit
PVVK-SV Single Flue Vertical Vent Kit
PVVTC Vertical Termination Cap - 1-1/2”
T24V 24 Volt Thermostat
TMV2 Two-Stage Thermostats
TDV1 Wall Thermostat - Wireless Remote
PVVK24H Coaxial Horizontal Direct Vent Kit (24”)
PVVK48H Coaxial Horizontal Direct Vent Kit (48”)
TRW Wall Thermostat - Wireless Remote
Bay Window Mantis
CIFPB-1C Corner Floor Pad Kit
CIPFP-1 Floor Pad Kit
PV-2H Slim Top Cover Kit
PV-4H Short Top Cover Kit
PVE-1 Metal Surround Kit, 35”
PVE-2 Metal Surround Kit, 38”
PVPK Pedestal Kit
PVSH Rear Shroud
Fireplace Mantis
FWK28(BL,CM,HP,SS) In-Wall Surround Kit, Picture Frame
FGK28(BL,SS) In-Wall Surround Kit, Louverless
FIK28(BL,CM,HP,SS) Insert Package
FFK28(BL,CM,HP,SS) Fireplace Mantel Surround Kit