Owner`s manual
27020-3-0410Page 8
Bay Window Models B(F,I,P)28(B,C,G)M
Input BTU/HR (KW/H) 19,000 Rear - 9,000 Front
Height 25 1/8”
Width 28 3/16”
Depth 17 5/8”
Gas Inlet (Pipe) 3/8” Flair
Electrical - Unit has a 5’ (1.5 m) 3 pronged cordset for con-
nection to an approved 115 VAC 60 Hz maximum
AMPs - 5A wall receptacle.
SPECIFICATIONS
INSTALLATION INSTRUCTIONS - GENERAL SAFETY INFORMATION
1. This installation must conform with local codes or, in the
absence of local codes with NFPA54.
2. Provide adequate clearances around the product for servicing
and ensure there are no obstructions to the combustion air
intake situated at the back of the heater. Refer to Pages 14 and
15.
3. The appliance must be installed on a at, solid continuous
surface (i.e. wood, metal, concrete). Please Note: Rough
or uneven surfaces can cause vibration or humming in the
heater.
4. The Mantis Power-Vent High-Effeciency Fireplace can be
installed in a wide variety of ways and will t nearly any
room layout. For installation options refer to Pages 14 and
15.
5. This appliance (Insert and Freestanding Models) needs to be
installed in such a way that the heater can be removed at all
times to service the heater exchanger and ue fan located in
the rear section of the heater.
Note: Under no circumstances should the appliance be
installed under conditions which would not allow for
easy removal of the appliance to carry out routine
inspection and service to the appliance, to do so will
void the warranty.
Note: On Single Wall ue pipe installations (imitation
zero clearance replace) a minimum of 2” (50.8 cm)
clearance must be provided at the rear of the heater to
enable the heater to get sufcient combustion air to the
air inlet located at the rear of heater. Refer to installation
instructions on Pages 14 and 15.
Note: Where a mantel surround is being used on insert
installations and zero clearance replace installations,
the combustion air intake slot located in the top mantel
surround must have no obstructions to allow combustion
air to enter through the slot to the combustion air inlet
located at the back of the heater.
Flat Front Models F(F,I,W)28BM(N,P)
Input BTU/HR (KW/H) 15,000 Rear - 13,000 Front
Height 24 9/16”
Width 28”
Depth 17 3/16”
Gas Inlet (Pipe) 3/8” Flair
Electrical - Unit has a 5’ (1.5 m) 3 pronged cordset for con-
nection to an approved 115 VAC 60 Hz maximum
AMPs - 5A wall receptacle.
Accessories
Common
Part Number Description
FRBTC Battery Operated Remote with Thermostat
FRBTP
Battery Operated Remote with Programmable
Thermostat
PVCA Colinear Adapter
PVCT Colinear Transition
PVVK24H Direct Vent 24” Vent Kit
PVVK48H Direct Vent 48” Vent Kit
PVVK-CFA Flex Vent Kit
PVVK-SH Single Flue Horizontal Vent Kit
PVVK-SV Single Flue Vertical Vent Kit
PVVTC Vertical Termination Cap - 1.5”
T24V 24 Volt Thermostat
TMV2 Two-Stage Thermostats
TRW Wall Thermostat - Wireless Remote
TDV1 Wall Thermostat - Wireless Remote
Bay Window
CIFPB-1C Corner Floor Pad Kit
CIPFP-1 Floor Pad Kit
PV-2H Top Cover - Slim Assembly
PV-4H Top Cover - Short Assembly
PVE-1 6” Surround Assembly
PVPK Pedestal Kit
PVSH Rear Shroud
TRW Wall Thermostat - Wireless Remote