Owner`s manual
27020-3-0410 Page 31
DIRECT VENT INSTALLATION INSTRUCTIONS
EXTERIOR GRADE
FLUE CENTER
1 1/4”
(3.2cm)
MIN.
12”
(30.5cm)
MIN.
FLOOR PROTECTION
FLOOR PROTECTION
NO HEARTH REQUIRED
EXTERIOR GRADE
FLUE CENTER
1 1/4”
(3.2cm)
MIN.
12”
(30.5cm)
MIN.
Figure 38
Minimum Exterior Grade Dimension - Unit Without Pedestal
Figure 39
Minimum Exterior Grade Dimension - Unit With Pedestal (Bay Window Models Only)
Installation on Rugs and Tile
If this appliance is to be installed directly
on carpeting, tile, or other combustible
material, other than wood ooring, the
appliance shall be installed on a metal or
wood panel extending the full width and
depth of the appliance.
The base referred to above does not mean
the re-proof base as used on wood stoves.
The protection is primarily for rugs that may
be extremely thick and light-color tile that
can discolor.
EXTERIOR GRADE
FLUE CENTER
12”
(30.5cm)
MIN.
Figure 40
Minimum Exterior Grade Dimension - Existing Fireplace Installation