Owner`s manual

27020-3-0410 Page 31
DIRECT VENT INSTALLATION INSTRUCTIONS
EXTERIOR GRADE
FLUE CENTER
1 1/4”
(3.2cm)
MIN.
12”
(30.5cm)
MIN.
FLOOR PROTECTION
FLOOR PROTECTION
NO HEARTH REQUIRED
EXTERIOR GRADE
FLUE CENTER
1 1/4”
(3.2cm)
MIN.
12”
(30.5cm)
MIN.
Figure 38
Minimum Exterior Grade Dimension - Unit Without Pedestal
Figure 39
Minimum Exterior Grade Dimension - Unit With Pedestal (Bay Window Models Only)
Installation on Rugs and Tile
If this appliance is to be installed directly
on carpeting, tile, or other combustible
material, other than wood ooring, the
appliance shall be installed on a metal or
wood panel extending the full width and
depth of the appliance.
The base referred to above does not mean
the re-proof base as used on wood stoves.
The protection is primarily for rugs that may
be extremely thick and light-color tile that
can discolor.
EXTERIOR GRADE
FLUE CENTER
12”
(30.5cm)
MIN.
Figure 40
Minimum Exterior Grade Dimension - Existing Fireplace Installation