Owner`s manual

27020-3-0410Page 14
BAY WINDOW CLEARANCE TO COMBUSTIBLES
Freestanding Models
Freestanding Units
A Rear Wall to Heater 0” (2” Single Flue and 1 1/4” Direct Vent for Serviceability)
B Side Wall to Heater 0” (4” recommended for serviceability)
C Corner Installation 0”
D Mantel Clearance See Figure 7
Fireplace Insert
Note: The Mantis Power-Vent High-Efciency Fireplace has been tested and approved for zero clearance to combustible materials.
Empire Comfort Systems, Inc. recommends that clearances as listed above should be maintained to allow for removal of the
product for servicing.
C
C
A
BB
Figure 3 Figure 4
Single Flue
Requires surround for combustion air.
Do not cover surround louver.
Figure 5
33 1/4”
(84.5cm)
29 3/4”
(75.6cm)
12”
(30.5cm)
26 ½”
(67.3cm)
35 7/16”
(90.0cm)
WALL OPENING
D
LOUVER
Mantel and Ceiling Clearances
Figure 7
Direct Vent Installation Shown
Single Flue requires surround for combustion air.
Figure6
12”
18”
24”
8”
6”
4”
COMBUSTIBLE TRIM AND MANTELS
ALLOWED IN SHADED AREA
40”
CEILING