Installation Guide

MantelMount MM860 PAGE 15
MantelMount MM860 Utility Software Package (3 Modules):
This utility must be loaded onto a PC or laptop in order to configure the MantelMount MM860
The MM860 Utility and MM860 Firmware are available for download at MantelMount.com - (Dealer)
Module 1:
Auto-Discover
This tool will automatically
identify each MM860 unit
on a network by their
IP and MAC addresses.
Module 1 provides access
to Module 2 and Module 3
Module 2:
Configuration
(Device page, Network Page)
This web page is hosted on
the MM860 unit. It contains
all network information, it is
used to update firmware,
and it accesses basic
MM860 parameters.
Module 3:
Toolbox
This tool gives access to
more detailed MM860
parameters for fine tuning
and trouble-shooting.
Auto Discover
Firmware Version
Elevation
0
545
0
0
0
False
29C
OK
0
0
0
True
True
0
0
False
Azimuth
Left Position
Right Position
TV On
Temperature
Status
TV Current
3/18/2019 12:46:33 PM
Last Pol:
Memory Index
Last Event Source
Left at Limit
Right at Limit
Left Motor Current
Right Motor Current
Lost
Connected to MantelMount 860
Connecting...
RECV MIV
Low Image Version: 0
High Image Version: 0
Low Image CRC: 0
High Image CRC: 0
RECV MMQ
0,0,0,-4,0,0,29,0,0,545,0,0,1,1,0,0,
192.168.150.111
IP Address
Version 1.0.1.6
Refresh Interval
100
ms
UDP Port
Save 1
Stow
Save 2
Save 3
Recall 1
Recall 2
Recall 3
Control Module Status
MantelMount Toolbox
File Options Help
Jog
Memory
MM860
Configuration
QueryConnect
Reset Clear Fault
Continuous
81
X
NETWORK DEVICE
This device is running rmware version 545(A)
There are currently no software updates available
Enabled (recommended)
0.00
0.00
Normal
O
Smooth Start Mode:
Current Swivel (Degrees -L or +R):
Current Elevation (Degrees):
Temperature Sensor:
0
55
15
Current TV Power:
mA
mA
mA
TV “On” Power Threshold:
TV “O” Power Threshold:
TV Status:
Check for update Local Update
Save Settings
Device Conguration
Status:
ALPS TV Settings: (Auto Lowering Power Sensing):
Network Adapter
Completed Scan
Discover MantelMount Devices
Ethernet
Network Adapter Information:
Subnet : 255 . 255 . 255 . 0
MAC: ECAAA02854DD
IP : 192 . 168 . 150 . 2
192.168.150.111 D83AF584E321
IP MAC Hostname
Scan Network
MM860
Conguration
MM860 Toolbox
X
NETWORK DEVICE
MAC Address:
Host Name:
MantelMount_f30190
d8:3a:f5:f3:01:90
192.168.150.111
192.168.150.1
255.255.255.0
81
81
IP address:
Determine network settings
automatically with DHCP
Use these network settings:
Subnet:
Gateway:
TCP Port:
UDP Port:
Save Settings
Network Information
Network Settings
MAC Address: d8 : 3a : f5 : xx : xx : xx
Host Name: MantelMount_xxxxxx
Unique to each MM860
Used in the Host Name
Start Here
IP address: 192.168.150.111
MM860 Default Settings:
MM860
Utility
DiscoverCongure
Device & NetworkToolbox
Troubleshoot