Installation Guide
MantelMount MM860 PAGE 11
UP
DOWN
RIGHT
LEFT
HOME
SET
M 2
M 1
UP
DOWN
RIGHT
LEFT
HOME
SET
M 2
M 1
Adjusting the Hard Bottom
Stop Position:
Jog the mount to the maximum safe
downward position. Do not swivel the
mount sideways. The mount may stop
on its own due to the internal limit.
Loosen the Locknuts and adjust the
Bottom Stop screws to this position.
Tighten both locknuts after the
adjustments are made.
Adjusting the Soft Side Swivel
Stop Position:
Adjusting the Soft Bottom
Stop Position:
Adjusting the Hard Side Swivel
Stop Positions:
Jog the mount to the maximum safe
RIGHT side position. Do not raise or
lower the mount.
Loosen the Locknut and adjust the
Swivel Stop screw to the desired
stopping position. Note: The locknut can
be moved to the other side of the Swivel
Bracket to increase the thread length.
Proceed to Step 19 to set the Soft Stop.
Repeat for the other side.
Adjusting the Downward Hard and Soft Travel Stops - FIRST:
16 17
18 19
a. Once the hard stop is set, jog the mount up slightly from the
Hard Stop. This will ensure the mount never hits the Hard Stop.
DO NOT JOG THE MOUNT INTO THE HARD STOP!
b. On the Electronics Housing, quick-press the “Program” Button
and verify that the Status light slow blinks.
c. On the Remote, Press the “SET” button and then within 2
seconds press the “DOWN” button. The Soft Stop should be set.
Repeat step (c) if the SET button exceeds the 2 second timeout.
d. Press the Program Button again to exit Program Mode.
a. Once the RIGHT hard stop is set, jog the mount slightly
inward from the Hard Stop. This will ensure the mount
never hits the Hard Stop.
DO NOT JOG THE MOUNT INTO THE HARD STOP!
b. On the Electronics Housing, quick-press the “Program”
Button and verify that the Status light slow blinks.
c. On the Remote, Press the “SET” button and then within
2 seconds press the “RIGHT” button. The RIGHT Soft Stop
should be set. Return to STEP 18 for other side.
d. Press the Program Button after the Soft Stops are set in
order to exit Program Mode.
Adjusting the Side Swivel Hard and Soft Travel Stops - SECOND:
LEFT
MOTOR
ETHERNETIRDA
RIGHT
MOTOR
MM-MC2
Input 100-240V ~ 50/60Hz, 1.6A
860
Status
Program
Reset