Datasheet

BENCH TOP
Single Output DC Regulated Power Supply
(Linear mode)
This series of low ripple and noise, adjustable
voltage power supplies are designed for
telecommunication field, workshop, production
line and college. The special designed trifler
wound transformer with thermal fuse and the
extensive overload protection by dissipation
limiting circuitry for the pass transistors make
this series proven and well known for its
reliability and stability.
Over Temp. protection for EP-912/920/925
3 - 15V DC adjustable output
Fixed voltage mode at 13.8V DC
Overload and short circuit protection
Overload warning LED indicator
High stability
Precision ammeter and voltmeter
One screw on and 2 snap on terminals
Galvanized steel case
Fan cooling system for models over
200VA (constant speed at all time)
Output current limit is depended on output
voltage
Description Features
All values are based on the Standard ambient Temperature 25°C and Pressure 0.1Mpa.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE
Specifications
Variable Output Voltage
Fixed Output Voltage
Rated Output Current
Ripple & Noise (r.m.s.)
Peak Output Current
Load Regulation (0-100% load)
Curr. Meter Range
Line Regulation (±5% variation)
Input Voltage
Volt. Meter Range
Meter Accuracy
Cooling System
Protection Devices
Approvals
Dimensions (WxHxD)
Weight
Accessories
Models
EP-907
6A
7A
40mV
0-10A
15mV
3-15VDC
13.8VDC
10mV
230VAC 50Hz~ (120VAC 60Hz~ or on request)
0-20V
7% fsd
Natural
Convection
Overload, Short Circuit
CE EN 60065, EN 55014
150x145x200mm
5.9x5.7x7.9inch
150x145x300mm
5.9x5.7x11.8inch
150x145x300mm
5.9x5.7x11.8inch
150x145x300mm
5.9x5.7x11.8inch
4.5kgs / 9.9lbs 5.5kgs / 12lbs 7kgs / 15.4lbs 9kgs / 19.8lbs
User Manual
EP-912
12A
15A
60mV
0-15A
EP-925
5 www.manson.com.hk
EP-Series
EP-920
18A
20A
80mV
0-20A
EP-925
25A
30A
100mV
0-30A
Thermostatic
control fan
Thermostatic
control fan
Thermostatic
control fan
0 2 4 6 8 10 12 14 15
10
20
30
Output Current ( A )
Output Voltage ( V )
EP - 907
EP - 912
EP - 920
EP - 925
The current of the unit is depended on the output
voltage as the following curve.

Summary of content (1 pages)