Specifications
63
For complete equipment specifications visit our website at www.hobartcorp.com
Warewashing & Waste Equipment
FLIGHT-TYPE AUTOMATIC RACK CONVEYOR DISHMACHINES
FT900D (Dual Rinse) Series
FT900SD
Entire FT900 Series is listed by UL, Certified by NSF and meets requirements of ASSE Standard No. 1004.
Many additional variations of these model specifications are available.
&OHJOFFSJOHEBUB GVSOJTIFEPOSFRVFTU%VBM3JOTF '5 GMJHIU UZQFNPEFMTJO
DPOKVODUJPOXJUI0QUJ3JO4F
™
allows the FT900D series to consume the lowest
amount of final rinse water in the industry.
Numbers in parentheses, below model number from left to right, represent
MFOHUI JO GFFU PG UIF GPMMPXJOH SFTQFDUJWFMZ -PBEJOH TFDUJPO 8BTIJOH BOE
Power Rinsing sections, Dual Rinse section, Unloading section.
Dual Rinse flight-type dishwasher with BLOWER-DRYER OPTION has the same
specifications as the Basic FT900 Series EXCEPT for one additional Blower
.PUPS )1 o BOE BOE JT BWBJMBCMF PO BOZ NPEFM
having an unload section 9 feet or longer.
Available with Energy Recovery –
MODEL NO.
FT900D Series (5,7/8/5,7,9,11) FT900SD Series (5,7/4/5,7,9,11)
Machine Ratings (Mechanical)
See 1 Page 70
Conveyor Speed – Feet per minute
4 - 8.5 4 - 6.3
Floor Space – Feet – Add 10
1
⁄
2
UPMFOHUIPG
machine for load and unload platforms.
%FUFSNJOFECZUIFDPNCJOBUJPOPGWBSJPVT
lengths in loading and unloading ends.
&YBNQMF'5GUMPOH
&YBNQMF'54GUMPOH
Overall Dimensions (H x W) Y
1
⁄
8
Y# Y
1
⁄
8
Y#
Motor – Hobart Designed – See 2 Page 70
H.P.
Pre-Wash 3 - Wash 3 - Rinse 3 - Conveyor
1
⁄
2
Dual Rinse
1
⁄
6
Pre-Wash 3 - Wash 3 - Conveyor
1
⁄
2
Dual Rinse
1
⁄
6
Blower-Dryer Motor H.P. *GVTFE 2 2
Electric Blower Dryer – Heating Coil
*GVTFE6--JTUFE
20 KW 20 KW
Steam Blower-Dryer – Based on 20 PSI & Flowing
4UFBN*GVTFE14*(NBY
75 lbs./hr. 75 lbs./hr.
Tank Capacity – Gallons
Pre-Wash 40 - Wash 40 - Rinse 40 -
Dual Rinse 10
Pre-Wash 40 - Wash 40 - Dual Rinse 10
Pump Capacity – See 3 Page 70
Gals. per min. – Weir Test
Pre-Wash 150 - Wash 290 - Rinse 290 -
Dual Rinse 8.5
Pre-Wash 150 - Wash 290 - Dual Rinse 8.5
Heating Equipment – See 4 Page 70
(For keeping power wash and/or power rinse
water hot).
3FHVMBUFE4UFBN*OKFDUPSTo4QFDJGZ
Regulated Steam Coils
Regulated Electric
When electric heat is specified on any flight type or automatic conveyor dishwashers,
disconnect switches are recommended for each power circuit connected to dishwasher.
These disconnect switches are NOT furnished by Hobart and should be installed in the power
circuits ahead of the dishwasher by the electrical contractor at the time of installation.
Circuit breakers optional at extra cost.
52 KW and 10 KW for Dual Rinse 46 KW and 10 KW for Dual Rinse
Rinse – See 5 Page 70
Minutes operated during hr. of capacity operation
60 60
Rate of Rinse Flow – at 20 PSI
Flow Pressure Gals. per min.
1.5 1.2
Rinse Consumption – Gals. per hour
At 20 PSI flow Pressure
90 72
Steam Consumption – Pounds per hour – Maximum
"QQSPYMCTQFSISCPJMFS)1#)1
Dishwasher, based on 15 to 52 PSI steam at
the machine and on customer supplying final
SJOTFXBUFSBUMJTUFENJOJNVN¡'14*(
Hot Water Sanitizing
175 lbs./hr.
Hot Water Sanitizing
175 lbs./hr.
Steam Booster, if used, based on 20 PSI steam at
- 20 PSI water flowing - 120°F. entering water,
SBJTFEUP¡'¡'SJTF¡'NJO
60 lbs./hr. 50 lbs./hr.
Exhaust Requirements – Cubic feet per minute
4JOHMFQPJOUDPOOFDUJPOPWFSDFOUFSTFDUJPO
XP#MPXFS%SZFSX#MPXFS%SZFS XP#MPXFS%SZFSX#MPXFS%SZFS
Peak Rate of Drain Flow – Gals. per min.
*OJUJBMSBUFXJUIGVMMUBOL
38 38
Shipping Weight Crated Varies by individual model - consult your Hobart representative
" *GPOMZ14*(4UFBN1SFTTVSFBWBJMBCMFBUNBDIJOFTQFDJGZ-PX1SFTTVSF4UFBN0QUJPO
# 8JUIBMMSFBSQBOFMTBOEQMVNCJOHSFNPWFENBDIJOFXJEUIJT
1
⁄
8
0WFSBMMIFJHIUUPUPQPGDPOUSPMCPYJT
1
⁄
16
$ )JHIFTUJUFNJTDPOUSPMCPY
11
⁄
16