Service Manual

Table Of Contents
Part Number 000015433_02 11/19 29
Heavily Scaled Cleaning Procedure
Perform this procedure if you have some or all of these
symptoms.
Excessive grinding, popping or squealing noises from
the evaporator
Grinding noise from gearbox
Ice machine trips speed sensor
NOTE: A Cleaning/Sanitizing Procedure must be performed
after this procedure.
Procedure to Clean Heavily Scaled Flake Ice Machines
Step 1 Remove front and top covers and set the toggle
switch to the OFF position.
Step 2 Remove all ice from the bin.
Step 3 Turn off the ice making water supply.
Step 4 Remove the top cover from water reservoir.