Use and Care
Operation Section 3
14
 Part Number 040002909 5/13
Ice Making Sequence of Operation
NOTE: The On/Off button must be depressed and the 
ice damper must be closed before the ice machine will 
start.
Water Purge Cycle
The ice machine purges any remaining water from the 
water trough down the drain. 
Freeze Cycle
Prechill - The refrigeration system chills the evaporator 
before water flow over the evaporator starts. The water 
inlet valve energizes during the pre-chill and remains on 
until the ice thickness float switch is satisfied.
Freeze - Water flowing across the evaporator freezes 
and builds ice on the evaporator. After a sheet of ice has 
formed, the harvest float switch signals the control board 
to start a harvest cycle.
Harvest Cycle
Any remaining water is purged down the drain as 
refrigerant gas warms the evaporator. When the 
evaporator warms, the sheet of cubes slides off the 
evaporator and into the storage bin. If all cubes fall clear 
of the ice damper the ice machine starts another freeze 
cycle.
Full Bin Cycle
If the ice damper is held open by ice cubes the ice 
machine shuts off. When the ice damper closes the ice 
machine starts a new cycle at the water purge. 
Control Board Timers
The control board has the following non-adjustable 
timers:
• The ice machine is locked into the freeze cycle for 6 
minutes before a harvest cycle can be initiated. 
• The maximum freeze time is 60 minutes at which 
time the control board automatically initiates a 
harvest sequence.
• The maximum harvest time is 3.5 minutes. The 
control board automatically initiates a freeze 
sequence when these times are exceeded.
SAFETY LIMITS
Safety limits are stored and indicated by the control 
board. The number of cycles required to stop the ice 
machine varies for each safety limit. 
Safety limits can be reset by pressing the On/Off button 
and starting a new ice making cycle.
A safety limit is indicated by a flashing Service Light on 
the touch pad. Refer to Section 5 if you receive a safety 
limit indication.
• Safety Limit 1 - If the freeze time reaches 60 minutes, 
the control board automatically initiates a harvest 
cycle. If 6 consecutive 60-minute freeze cycles occur, 
the ice machine stops.
• Safety Limit 2 - If the harvest time reaches 3.5 
minutes, the control board automatically returns the 
ice machine to the freeze cycle. If 500 consecutive 
3.5 minute harvest cycles occur, the ice machine 
stops.
• Safety Limit 3 - If the freeze time reaches 4 minutes 
and water is not sensed, the ice machine stops and 
initiates a 30 minute delay period. The ice machine 
will automatically restart at the end of the 30 minute 
delay period. If 100 consecutive failures occur the ice 
machine stops.