Service Manual

Table Of Contents
160 Part Number 8014793 6/18
Self-Contained Charging Procedures
1. Be sure the toggle switch is in the OFF position.
Important
The charge is critical on all Manitowoc ice
machines. Use a scale to ensure the proper
charge is installed.
MANIFOLD SET
CLOSED
FRONTSEATED
SCALE
VACUUM PUMP/
RECOVERY UNIT
OPEN
CLOSED
LOW SIDE
SERVICE
VALVE
HIGH SIDE
SERVICE
VALVE
BACKSEATED
OPEN
REFRIGERANT
CYLINDER
CHARGING CONNECTIONS