Troubleshooting guide
Installation and Service Manual
23
USER MAINTENANCE
MONTHLY CLEANING
CLEANING AND SANITIZING OF THE DISPENSER
Note: Sanitize the dispenser at initial start-up in addition to monthly sanitizing.
Mix a solution of mild, nonabrasive detergent to clean the dispenser bin and components. Using a clean cloth or a
soft bristle brush, clean the following dispenser parts:
• Cold plate
• Ice storage bin, including the
• Agitator
• Agitator Pin
• Bin liner & support
• Drainpan support bracket
• Auger
• Auger tube
• Auger transition
• Ice chute outer bracket
• Ice chute
• Ice chute door
• Ice chute lock
• Ice chute spout
• Paddle wheel
• Paddle wheel bushing
• Paddle wheel area
Rinse all parts in clean, running water. Mix a sanitizing
solution of ¼ ounce liquid, unscented laundry bleach
(5.25% Cl Na O concentration) for each gallon of water,
to supply 100 PPM of available chlorine. Using this so-
lution and a clean cloth or soft bristle brush, clean the
dispenser parts listed above. Allow parts to air-dry then
reassemble.
Scheduled cleaning must be in compliance with local health codes. This cleaning schedule is a
recommendation. Follow cleaning and sanitizing instructions found in the Manitowoc manual to
clean and sanitize the icemaker. The LP-3 drainpan and splash panel must be removed before