Troubleshooting guide

12
Installation and Service Manual
INSTALLATION
PURGE TUBE ROUTING
1. During installation of the LP-3 the carbonator tank
purge tube (A) must be properly routed to a drain.
The carbonator tank purge tube (A) may be ac-
cessed by removing the front panel of the LP-3. Clip
the tie strap (B) and uncoil the purge tube (A).
(see figure 1)
2. Route the carbonator tank purge tube (A) to the
opening beneath the ice bin drain elbow (C). Be
sure not to collapse or kink the carbonator tank
purge tube (A) during routing from the unit to the
drain. The purge tube (A) is connected to the pres-
sure relief valve (D) on the carbonator tank and must
be routed to a drain.
(see figure 2)
3. Strap the carbonator tank purge tube to the drain
hose and route to a drain. Follow all local and na-
tional plumbing codes when routing the carbonator
tank purge tube to the drain.
Pressure 
Relief Valve
B
A
FIGURE 1
FIGURE 2
C
D
A