Troubleshooting guide

10
Installation and Service Manual
INSTALLATION
ICEMAKER REQUIREMENTS
The LP-3 may be equipped with a Manitowoc® SU1024YC icemaker. Refer to the Manitowoc® Ice/Beverage Series
QuietQube® Ice Machines with CVD® Technology Installation, Use and Care Manual for additional information. See
also the "MANITOWOC®
SU1024YC ICEMAKER" section in this manual for exploded views and parts lists.
1. Incoming tap water should be at a minimum pres-
sure of 40 psi and a maximum of 55 psi with carbon-
ator pump operating (measured at inlet to pump).
2. BIB pressure gauge set for 60 psi or according to
the legnth of the line run.
1. To access the toggle switch for the ice maker lift
and turn the latch at the front of the lid
(see the Covers and Panels section item 5).
2. Using the latch and rubber handle, lift the lid off
3. The toggle switch is located on the back right cor-
ner. Switch forward for ON, center for OFF and back
for CLEAN.
COLD CARB AND AMBIENT SYSTEM PRESSURES
NOTE: To turn the SU1024YC ice maker on and off and put in clean mode you need to access the toggle switch.
3. Carbonator Pressure gauge (Use Preset Regulator):
Cold Carbonation set for 75 psi.
NOTE: If incoming water pressure is under 40 psi, a
water booster is required. If incoming water pressure is
over 55 psi, a water regulating valve is required.
CARBONATED/NON-CARBONATED
CONVERSION INSTRUCTIONS