Spec Sheet

Model
Ice
Shape
Ice Production 24 Hours
70°Air/50°F
Water
90°Air/70°F
Water
lbs. kgs. lbs. kgs.
IDT-0420A dice 470 213 375 170
IDT-0420W dice 454 206 400 181
IYT-0420A half-dice 460 209 375 170
IYT-0420W half-dice 490 222 425 193
Model
Ice
Shape
Ice Production 24 Hours
70°Air/50°F
Water
90°Air/70°F
Water
lbs. kgs. lbs. kgs.
IDT-0620A dice 560 254 450 204
IDT-0620W dice 530 240 450 204
IYT-0620A half-dice 575 261 465 211
IYT-0620W half-dice 560 254 485 220
2110 South 26th Street
Manitowoc, WI 54220
Tel: 1.920.682.0161
Fax: 1.920.683.7589
Installation Note - Dispensers have no minimum clearance, when installing an ice machine/
dispenser combination follow the clearance requirements for the ice machine being installed.
www.manitowocice.com
4358M 09/2021
©2018 Welbilt, Inc.
SPA-162 • SFA-192 Touchless Ice Dispensers
A
B
C
D
E
F
G
24.50" (62.23 cm)
21.50"
(54.60 cm)
48.00"
(121.92 cm)
6.00"
(15.24 cm)
22.00"
(55.88 cm)
31.19"
(79.22 cm)
FF
GG
H
H
Electrical Entrance (2) Options
3/8" (0.95 cm) F.P. T. Water Condenser
Inlet (water-cooled units)
1/2" (1.27 cm) F.P. T. Water Condenser
Outlet (water-cooled units)
3/8" (0.95 cm) F.P. T. Ice Making Water Inlet
1/2" (1.27 cm) F.P. T. Ice Making Water Drain
Dispenser Electrical Entrance
1/2" (1.27 cm) F.P. T. Melting Tray Pan Drain
Floor To Drain Distance = 13" (With 6" legs)
Water Inlet: SFA-191 only
B
A
C
D
E
F
Series iT0420 (115 volt)
Series iT0620 (115 volt)
AR-Pre-P
Filters dirt, rust, and
hard sediments down
to 5 micron.
Arctic Pure Plus Water Filters
AR-10000-P
Ultra-fine filtration reduces
chlorine & contaminants
down to .5 microns. Use of
pre-filter recommended.
LuminIce® II
Virus and Bacteria
Inhibitor
controls viruses and
bacteria inside the ice
machine
iT0420 or iT0520
Ice Machines
SPA-160
or SFA-191
Ice Dispenser
Ice Machine Electric
Note: Dispenser will accept single 22"
wide ice machine. Ice machine ordered
separately. Choose Dice or Half Dice cube
size. Refer to ice machine specification
sheet for electrical and complete AHRI
standard ratings.
Dispenser Electric:
115/60/1. (208-230/60/1 and 230/50/1
also available.)
Maximum Circuit Fuse Size:
15.0 amps. HACR-type circuit breakers can
be used in place of fuses.
Dispenser Electrical Connection:
6' power cord, rated 125 VAC, 16-3
conductors with standard 3-prong,
straight-blade, ground-type plug (NEMA
configuration 5-15P).
Motor:
1.6 amps maximum. Permanently
lubricated.
Service Access:
Dispenser door removes easily to
access components.
Model Options:
SPA-162 touch-less activated lever only
SFA-192 touch-less activated lever with
water valve