Specification Sheet

Model
Ice
Shape
Ice Production 24 Hours
70°Air/50°F Water 90°Air/70°F Water
lbs. kgs. lbs. kgs.
IDT-0420A dice 470 213 375 170
IDT-0420W dice 454 206 400 181
IYT-0420A half-dice 460 209 375 170
IYT-0420W half-dice 490 222 425 193
Model
Ice
Shape
Ice Production 24 Hours
70°Air/50°F Water 90°Air/70°F Water
lbs. kgs. lbs. kgs.
IDT-0620A dice 525 238 410 186
IDT-0620W dice 560 254 450 204
IYT-0620A half-dice 530 240 450 204
IYT-0620W half-dice 575 261 465 211
2110 South 26th Street
Manitowoc, WI 54220
Tel: 1.920.682.0161
Fax: 1.920.683.7589
Installation Note - Dispensers have no minimum clearance, when installing an ice machine/dispenser
combination follow the clearance requirements for the ice machine being installed.
www.manitowocice.com
4358G 03/18
©2018 Welbilt, Inc.
SPA-160 • SFA-191 Ice Dispensers
A
B
C
D
E
F
G
24.50" (62.23 cm)
21.50"
(54.60 cm)
48.00"
(121.92 cm)
6.00"
(15.24 cm)
22.00"
(55.88 cm)
31.19"
(79.22 cm)
FF
GG
H
H
Electrical Entrance (2) Options
3/8" (0.95 cm) F.P. T. Water Condenser
Inlet (water-cooled units)
1/2" (1.27 cm) F.P. T. Water Condenser
Outlet (water-cooled units)
3/8" (0.95 cm) F.P. T. Ice Making Water Inlet
1/2" (1.27 cm) F.P. T. Ice Making Water Drain
Dispenser Electrical Entrance
1/2" (1.27 cm) F.P. T. Melting Tray Pan Drain
Floor To Drain Distance = 13" (With 6" legs)
Water Inlet: SFA-191 only
B
A
C
D
E
F
Series iT0420 (115 volt) Series iT0620 (115 volt)
AR-Pre
filters, dirt, rust
and sediment.
ArcticPure® Water Filters
AR-10000
reduces: scale, chlorine
taste, and odor. Ice
looks and tastes better.
LuminIce® II
Growth Inhibitor
reduces yeast and
bacteria growth for a
cleaner ice machine.
iT0420 or iT0520
Ice Machines
SPA-160
or SFA-191
Ice Dispenser
Ice Machine Electric
Note: Dispenser will accept single 22" wide
ice machine. Ice machine ordered separately.
Choose Dice or Half Dice cube size. Refer to ice
machine specification sheet for electrical and
complete AHRI standard ratings.
Dispenser Electric:
115/60/1. (208-230/60/1 and 230/50/1
also available.)
Maximum Circuit Fuse Size:
15.0 amps. HACR-type circuit breakers can be
used in place of fuses.
Dispenser Electrical Connection:
6' power cord, rated 125 VAC, 16-3 conductors
with standard 3-prong, straight-blade, ground-
type plug (NEMA configuration 5-15P).
Motor:
1.6 amps maximum. Permanently lubricated.
Service Access:
Dispenser door removes easily to
access components.
Model Options:
SPA-160 push-for-ice rocking chute,
SFA-191 has a water valve option.