Ice Thickness Probe
A. Compress the hinge pin on the top of the ice
thickness probe.
Ice Thickness Probe Removal
B. Pivot the ice thickness probe to disengage one
pin then the other. The ice thickness probe can
be cleaned at this point without complete
removal. Follow Step C for complete removal.
C. Disconnect the ice thickness control wiring from
the control board.
Water Distribution Tube
NOTE: Distribution tube thumbscrews are retained by o-
rings to prevent loss. Loosen thumbscrews but do not
pull thumbscrews out of distribution tube.
Water Distribution Tube Removal
A. Remove outer half of distribution tube by
loosening the four (4) thumbscrews (o-rings
retain thumbscrews to distribution tube).
B. Pull inner half of water distribution tube forward
to release slip joint from water pump tubing
connection.
!
Warning
Disconnect the electric power to the ice machine at
the electric service switch box.
SV3135
COMPRESS
HINGE PIN TO
REMOVE
!
Warning
Removing the distribution tube while the water
pump is running will allow water to spray from ice
machine. Disconnect the electrical power to the ice
machine and dispenser at the electric service switch
box and turn off the water supply.
A