Specifications

Part Number 000006520 10/09 5
Section 2
Installation Instructions
Location of Ice Machine
The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met,
select another location.
The location must be free of airborne and other
contaminants.
The air temperature must be at least 35°F (1.6°C),
but must not exceed 110°F (43.4°C).
Remote air cooled - The air temperature must be at
least -20°F (-29°C), but must not exceed 120°F
(49°C).
The location must not be near heat-generating
equipment or in direct sunlight and must be protected
from weather.
The location must not obstruct air flow through or
around the ice machine. Refer to the chart below for
clearance requirements.
Clearance Requirements
*There is no minimum clearance required for water-cooled or
remote ice machines. This value is recommended for efficient
operation and servicing only.
**S3300 - 24” on all sides is recommended to allow access without
moving the bin/ice machine.
S300
Self-Contained
Air-Cooled
Self-Contained
Water-Cooled
Top/Sides 16" (40.6 cm) 8" (20.3 cm)
Back 5" (12.7 cm) 5" (12.7 cm)
S320/S450/S500/
S600/S850/S1000
Self-Contained
Air-Cooled
Water-Cooled
and Remote*
Top/Sides 8" (20.3 cm) 8" (20.3 cm)
Back 5" (12.7 cm) 5" (12.7 cm)
S420
Self-Contained
Air-Cooled
Water-Cooled
and Remote*
Top/Sides 12" (30.5 cm) 8" (20.3 cm)
Back 5" (12.7 cm) 5" (12.7 cm)
S1200
Self-Contained
Air-Cooled
Water-Cooled
and Remote*
Top 8" (20.3 cm) 8" (20.3 cm)
Sides 12" (30.5 cm) 8" (20.3 cm)
S1400/S1600/S1800
Self-Contained
Air-Cooled
Water-Cooled
and Remote*
Top/Sides 24" (61.0 cm) 8" (20.3 cm)
Back 12" (30.5 cm) 5" (12.7 cm)
S3300** Water-Cooled
Top/Sides 8" (20.3 cm)
Back 24" (61.0 cm)
!
Caution
The ice machine must be protected if it will be
subjected to temperatures below 32°F (0°C). Failure
caused by exposure to freezing temperatures is not
covered by the warranty.