30 Part Number 000015433_03 5/20
Remedial Cleaning Procedure for Heavily
Scaled Ice Machines
Perform this procedure if you have some or all of these
symptoms.
• Excessive grinding, popping or squealing noises from
the evaporator
• Grinding noise from gearbox
• Ice machine trips speed sensor
NOTE: A Cleaning/Sanitizing Procedure must be performed
after this procedure.
Procedure to Clean Heavily Scaled Flake Ice Machines
Step 1 Remove front and top covers and set the toggle
switch to the OFF position.
Step 2 Remove all ice from the bin.
Step 3 Turn off the ice making water supply.
Step 4 Remove the top cover from water reservoir.