Part Number 000015433_03 5/20 83
BIN THERMOSTAT
Model Setting Cut-Out Cut-In
UFF0200 / UNF0200
UNF0300 / UFF0350
5
37°F ±1
3°C ±.1
43°F ±1
6°C ±.1
RFF0320 / RFF0620
RNF0620 / RNF1100
RNF1020C / RFF1300
RFF1220C / RNF2000C
RFF2200C / RFF2500
3
35°F ±1
1.6°C ±.1
41°F ±1
5.0°C ±.1
LOW TEMPERATURE THERMOSTAT
EVAPORATOR SAFETY THERMOSTAT
Model Setting Cut-Out Cut-In
UFF0200 / UNF0300
5
-1°F ±1
-17.2°C ±.1
39°F ±1
4°C ±.1
UNF0200 / UNF0300
RFF0320
6
-3°F ±1
-19.5°C ±.1
39°F±.1
4°C ±.1
RNF0320 / UFF0350
7
-8°F ±.1
-22°C ±.1
39°F±.1
4°C ±.1
Component Specifications