Service Manual
Part Number 000015433 5/18 83
BIN THERMOSTAT
Model Setting Cut-Out Cut-In
UFF0200 / UNF0200
UNF0300 / UFF0350
RFF1220 / RFF1300
5 37°F ±1
3°C ±.1
43°F ±1
6°C ±.1
RFF0320 / RFF0620
RNF0620 / RNF0320
RNF1100 / RNF1020
4 36°F ±1
2.2°C ±.1
42°F ±1
5.6°C ±.1
LOW TEMPERATURE THERMOSTAT
Evaporator safety thermostat)
Model Setting Cut-Out Cut-In
UFF0200 / UNF0200
UNF0300
5 -9°F ±1
-23°C ±.1
10°F ±1
-12°C ±.1
RFF0320 / RNF0320
UFF0350
7 -11°F ±.1
-24°C ±.1
7 °F±.1
-14°C ±.1
HIGH PRESSURE CUTOUT (HPCO) CONTROL
Model Cut-Out Cut-In
RNF0320 / RFF0620
RFF1300 / RNF0320
RNF0620 / RNF1100
325 psig ±10
(2250 kPa ±69)
22.5 bar ±.69
200 psig ±10
(1379 kPa ±69)
13.79 bar ±.69
Auto Reset
RFF2500 435 psig ±10
(3000 kPa ±69)
30 bar ±.69
Manual Reset
RNF1020C / RCUF1000
RFF1220C / RCUF1200
RFF2200C / RCUF2200
450 psig ±10
(3100 kPa ±69)
31 bar ±.69
300 psig ±10
(2068 kPa ±69)
20 bar ±20.68
Auto Reset
Component Specifications