Service Manual
Table Of Contents
- General Information
- Model Numbers
- Installation
- Maintenance
- Sequence of Operation
- Troubleshooting
- Component Specifications
- Charts
- Diagrams
- Wiring Diagrams
- Flake Models
- Nugget Models
- Condensing Units
- Compressor Start Component Wiring
- Refrigeration Tubing Schematics
- UFF0200/UFF0350/UNF0200/UNF0300
- RFF0320/RNF0320 Air-cooled
- RFF0620/RNF0620/RNF1100 Air & Water-cooled
- RNF1020C QuietQube Head Section & RCUF1000 Condensing Unit
- RFF1220C & RCUF1000 Condensing Unit
- RNF2000C QuietQube Head Section & RCUF2200 Condensing Unit
- RFF2200C QuietQube Head Section & RCUF2200 Condensing Unit
- RFF1300 Air & Water-cooled
- RFF2500 Air-cooled
Part Number 000015433_03 5/20 99
RFF2500A
SELF CONTAINED AIR-COOLED
Characteristics vary depending on operating conditions.
ICE PRODUCTION
Air Temperature
Water Temperature
24 hour
Ice Production
70°F/50°F
21°C/10°C
2301 lbs
1044 kgs
90°F/70°F
32°C/21°C
1665 lbs
755 kgs
OPERATING PRESSURES PSIG & kPa
Air Temperature
Entering
Condenser
Freeze Cycle
Discharge
Pressure
Suction
Pressure
70°F PSIG
21°C kPa
290-310
1999-2137
35-38
241-262
90°F PSIG
32°C kPa
350-380
2413-2620
38-43
262-296
110°F PSIG
43°C kPa
410-430
2827-2965
43-49
296-338