Part Number 000015433_03 5/20 93
RFF0620A
SELF CONTAINED AIR-COOLED
Characteristics vary depending on operating conditions.
ICE PRODUCTION
Air Temperature
Water Temperature
24 hour
Ice Production
70°F/50°F
21°C/10°C
747 lbs
339 kgs
90°F/70°F
32°C/21°C
506 lbs
230kgs
OPERATING PRESSURES PSIG & kPa
Air Temperature
Entering
Condenser
Freeze Cycle
Discharge
Pressure
Suction
Pressure
70°F PSIG
21°C kPa
240-265
1655-1827
33-35
228-241
90°F PSIG
32°C kPa
280-300
1930-2068
34-40
235-276
110°F PSIG
43°C kPa
340-370
2344-2551
40-46
275-318