Part Number 000015433_03 5/20 19
Installation Requirements
The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met,
select another location.
• Air temperature - Minimum 50°F (10°C), Maximum
110°F (43°C)
• The location must be free of airborne and other
contaminants.
• The location must not be near heat-generating
equipment or in direct sunlight.
• The location must be capable of supporting the weight
of the ice machine and a full bin of ice.
• The location must allow enough clearance for water,
drain and electrical connections in the rear of the ice
machine.
• The location must not obstruct airflow through or
around the ice machine.
• The ice machine and bin must be level.
• Routine adjustments and maintenance procedures
outlined in this manual are not covered by the
warranty.
Installation