UFF0200/UFF0350/UNF0200/UNF0300 Operation 
The ice machine will not start until:
A.  The rocker switch is moved to “ON”.
B.  Ice does not contact the bin thermostat bulb.
C.  The water reservoir is full of water.
Placing the toggle switch in the ON position starts the gear 
motor and refrigeration system. The float valve controls the 
water inlet valve and water level. The freeze cycle ends when 
ice contacts the bin thermostat. The ice machine will restart 
when ice no longer contacts the bin thermostat.
SENSING BULB IS 
LOCATED IN BIN
BIN THERMOSTAT 
LOCATION
EVAPORATOR LOW 
TEMPERATURE SAFETY 
THERMOSTAT LOCATION
RFF0320 & RNF0320 Operation
The ice machine will not start until:
A.  The rocker switch is moved to “ON”.
B.  Ice does not contact the bin thermostat bulb.
C.  The water reservoir is full of water.
Placing the toggle switch in the ON position starts the 
gear motor and a 10 minute compressor time delay. The 
compressor starts and the float valve controls the water 
inlet valve and water level. The freeze cycle ends when ice 
contacts the bin thermostat. The ice machine remains off 
until ice no longer contacts the bin thermostat.
BIN THERMOSTAT
EVAPORATOR 
THERMOSTAT
RNF0620/RFF0620/RNF1100/RFF1300/RFF2500 
Operation
The ice machine will not start until:
A.  The rocker switch is moved to “ON”.
B.  Ice does not contact the bin thermostat bulb.
C.  The water reservoir is full of water.
Placing the toggle switch in the ON position starts the gear 
motor. After the rotation speed sensor verifies 10 minutes 
of correct rotation, the time delay ends and the compressor 
starts. The ice machine will continue to make ice until ice 
contacts the bin thermostat. The ice machine remains off 
until ice no longer contacts the bin thermostat.
BIN THERMOSTAT IS 
LOCATED ON SIDE OF 
CONTROL BOX