22  Part Number 000015433_03 5/20 
Electrical Service
n
Warning
All wiring must conform to local, state and national 
codes.
VOLTAGE
The maximum allowable voltage variation is ± 10% of the 
rated voltage on the ice machine model/serial number 
plate at compressor start-up.
FUSE/CIRCUIT BREAKER
A separate fuse/circuit breaker must be provided for each 
ice machine. Circuit breakers must be H.A.C.R. rated (does 
not apply in Canada).
n
Warning
The ice machine must be grounded in accordance with 
national and local electrical codes.
GROUND FAULT INTERRUPTER CIRCUIT (GFIC)
A GFCI/GFI circuit protection is not recommended with 
our equipment. If a GFCI/GFI is required by code a GFCI/
GFI breaker rather than outlet must be used to avoid 
intermittent nuisance trips.