Manitowoc R Model Flake & Nugget Technician’s Handbook This manual is updated as new information and models are released. Visit our website for the latest manual. www.manitowocice.
Safety Notices As you work on Manitowoc equipment, be sure to pay close attention to the safety notices in this handbook. Disregarding the notices may lead to serious injury and/or damage to the equipment. Throughout this handbook, you will see the following types of safety notices: ! Warning Text in a Warning box alerts you to a potential personal injury situation. Be sure to read the Warning statement before proceeding, and work carefully.
Procedural Notices As you work on Manitowoc equipment, be sure to read the procedural notices in this handbook. These notices supply helpful information which may assist you as you work. Throughout this handbook, you will see the following types of procedural notices: Important Text in an Important box provides you with information that may help you perform a procedure more efficiently. Disregarding this information will not cause damage or injury, but it may slow you down as you work.
Read These Before Proceeding: ! Caution Proper installation, care and maintenance are essential for maximum performance and troublefree operation of your equipment. Visit our website www.manitowocfsg.com for manual updates, translations, or contact information for service agents in your area. Important Routine adjustments and maintenance procedures outlined in this handbook are not covered by the warranty.
! Warning This equipment contains high voltage electricity and refrigerant charge. Installation and repairs are to be performed by properly trained technicians aware of the dangers of dealing with high voltage electricity and refrigerant under pressure.The technician must also be certified in proper refrigerant handling and servicing procedures. All lockout and tag out procedures must be followed when working on this equipment.
! Warning Do not obstruct machine vents or openings. ! Warning Do not store gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. ! Warning Do not clean with water jet. ! Warning It is the responsibility of the equipment owner to perform a Personal Protective Equipment Hazard Assessment to ensure adequate protection during maintenance procedures. ! Warning Two or more people are required to move this equipment to prevent tipping.
! Warning When using electric appliances, basic precautions must always be followed, including the following: a. Read all the instructions before using the appliance. b. To reduce the risk of injury, close supervision is necessary when an appliance is used near children. c. Do not contact moving parts. d. Only use attachments recommended or sold by the manufacturer. e. Do not use outdoors. f. For a cord-connected appliance, the following must be included: • Do not unplug by pulling on cord.
Table of Contents General Information Model Numbers . . . . . . . . . . . . . . . . . . . . . 13 Self Contained Air & Water-Cooled Models . . . . . . . . . 13 QuietQube Remote Air-cooled Models with Remote Condensing Units . . . . . . . . . 14 Rack Units . . . . . . . . . . . . . . . . . . . . . . 14 Model/Serial Number . . . . . . . . . . . . . . . . 15 Manitowoc Cleaner and Sanitizer . . . . . . 15 Ice Machine Warranty Information . . . . . 15 Installation Installation Requirements . . . . . . . . . . . .
Maintenance Cleaning and Sanitizing . . . . . . . . . . . . . 21 Exterior Cleaning . . . . . . . . . . . . . . . . 21 RF/RFS/RNS Models Cleaning/Sanitizing Procedures . . . . . . . . . . . . . . . . . . . . . 22 Removal of Parts for Cleaning/Sanitizing 28 Ice Chute Removal - RFS Models . . . 30 Ice Chute Removal - RF Models . . . . 32 Ice Chute Switch Actuator Removal . . 33 RN Models Cleaning/Sanitizing Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Cleaning the Condenser . . . .
Troubleshooting Electrical Flowcharts . . . . . . . . . . . . . . . . 49 RF0244/RNS0244/RF0266/RF0385/ RFS0385/RNS0385/RF0388/RF0399 Air & Water . . . . . . . . . . . . . . . . . . . . . . . . . . 50 RF0300/RFS0300 Air & Water . . . . . . 55 RF0644/RF0650/RF1200/RFS1200/ RF2300/RFS2300 Air & Water . . . . . . 60 RF1200C/RFS1200C QuietQube Remote . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 RF2300/RFS2300C Air & Water . . . . . 71 RF2300C/RFS2300C QuietQube Remote . . . . . . . . . . . .
Charts Ice Production & Refrigerant Pressure . Flake Models . . . . . . . . . . . . . . . . . . . . . . RF0244A & RFS0244 . . . . . . . . . . . . . RF0266A . . . . . . . . . . . . . . . . . . . . . . RF0300A & RFS0300A . . . . . . . . . . . RF0385A . . . . . . . . . . . . . . . . . . . . . . RF0388A . . . . . . . . . . . . . . . . . . . . . . RF0399A . . . . . . . . . . . . . . . . . . . . . . RF0644A . . . . . . . . . . . . . . . . . . . . . . RF0650A . . . . . . . . . . . . . . . . . . . . . . RF0650W . .
Diagrams Wiring Diagrams . . . . . . . . . . . . . . . . . . . . 143 Flake Models . . . . . . . . . . . . . . . . . . . . . . . 144 RF0244/RNS0244/RF0266/RF0385/ RNS0385/RF0388/RF0399 Air-Cooled 144 RF0300/RFS0300 Air-Cooled . . . . . . . 146 RF0650/RF1200/RFS1200 Air-Cooled 148 RF1200/RFS1200 Water-Cooled . . . . 150 RF1200C/RFS1200C QuietQube Head Section . . . . . . . . . . . . . . . . . . . . . . . . 152 RF2300/RFS2300 Air-Cooled & Watercooled . . . . . . . . . . . . . . . . . . . . . . . . .
Refrigeration Tubing Schematics . . . . . 168 Flake Models . . . . . . . . . . . . . . . . . . . . . . 168 RF0244/RFS0244/RF0266/RF0300/ RF0385/RF0388/RF0399/RF0644/RF0650 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168 RF1200/RFS1200 Air-cooled . . . . . . . 170 RF1200/RFS1200 Water-cooled . . . . 172 RF2300/RFS2300 Air-cooled . . . . . . . 174 RF2300/RFS2300 Water-cooled . . . .
General Information Model Numbers SELF CONTAINED AIR & WATER-COOLED MODELS Flake Models Self Storage Air-Cooled Modular Self Storage Water-Cooled Air-Cooled Modular WaterCooled RF0244A – – – RF0266A – – – RF0385A – – – RF0388A – – – RF0399A – – – – – RF0300A – – – RFS0300A – – – – – – – RF0650A RF0650W – – RF0650A RF0650W – – RF1200A RF1200W – – RFS1200A RFS1200W – – RF2300A RF2300W Nugget Models Self Storage Air-Cooled Modular Self Storage Water-Coole
QUIETQUBE REMOTE AIR-COOLED MODELS WITH REMOTE CONDENSING UNITS Flake Models QuietQube Head RCU Remote Condensing Unit RF1278C RCU1075 RFS1278C RCU1075 RF2378C RCU2375 RFS2378C RCU2375 Nugget Models QuietQube Head RCU Remote Condensing Unit RN1078C RCU1075 RN1278C RCU1275 RACK UNITS Flake Models Head Section Rack Remote Condensing Unit RF1279R Supplied by Others RFS1279R Supplied by Others RF2379R Supplied by Others RFS2379R Supplied by Others NOTE: Rack units share a common refrig
Model/Serial Number These numbers are required when requesting information from your local Manitowoc Distributor, or Manitowoc Ice. The model and serial number are listed on the MODEL/SERIAL NUMBER DECAL affixed to the ice machine. Manitowoc Cleaner and Sanitizer Manitowoc Ice Machine Cleaner and Sanitizer are available in 16 oz. (473 ml) bottles. These are the only cleaner and sanitizer approved for use with Manitowoc products. Cleaner Part Number Sanitizer Part Number 16 oz. 000000084 16 oz.
This Page Intentionally Left Blank 18 Part Number 000007661 6/12
Installation Installation Requirements The location selected for the ice machine must meet the following criteria. If any of these criteria are not met, select another location. • Air temperature: Flake Models - Minimum 50°F (10°C), Maximum 110°F (43°C) Nugget Models - Minimum 50°F (10°C), Maximum 100°F (38°C) • The location must be free of airborne and other contaminants. • The location must not be near heat-generating equipment or in direct sunlight.
Potable Water Requirements • • • • • • • • Plumbing must conform to local codes. Water temperature: Minimum 40°F (4°C), Maximum 90°F (32°C). Do not connect the ice machine to a hot water supply. Be sure all hot water restrictors installed for other equipment are working. (Check valves on sink faucets, dishwashers, etc.) If water pressure exceeds maximum pressure (70 psig [483 kPa] RN1000; 80 psig [552 kPa] for all other models) obtain a water pressure regulator from your Manitowoc distributor.
Ice Machine Clearance Requirements Head Sections SelfContained Air-Cooled SelfContained Water-Cooled* Back 5" (12.7 cm) 5" (12.7 cm) 0" (0 cm) Sides/Top 8" (20.3 cm) 8" (20.3 cm) 0" (20 cm) QuietQube Air-Cooled RCU Units Remote Condensing Unit* Front/Back 24" (61.0 cm) Sides/Top 6" (15.2 cm)* * Water-Cooled Only - There is no minimum clearance required. This value is recommended for efficient operation and servicing only.
Electrical Service ! Warning All wiring must conform to local, state and national codes. VOLTAGE The maximum allowable voltage variation is ± 10% of the rated voltage on the ice machine model/serial number plate at compressor start-up. FUSE/CIRCUIT BREAKER A separate fuse/circuit breaker must be provided for each ice machine. Circuit breakers must be H.A.C.R. rated (does not apply in Canada). ! Warning The ice machine must be grounded in accordance with national and local electrical codes.
Maintenance Cleaning and Sanitizing Maintenance procedures covered in this manual are not covered by the warranty. ! Caution Use only Manitowoc approved Ice Machine Cleaner (part number 000000084) and Sanitizer (part number 9405653). Do not mix Cleaner and Sanitizer solutions together. It is a violation of Federal law to use these solutions in a manner inconsistent with their labeling. Read and understand all labels printed on bottles before use.
RF/RFS/RNS MODELS CLEANING/SANITIZING PROCEDURES Cleaning/Sanitizing Procedure This procedure must be performed once every month. • All ice must be removed from the bin • The ice machine and bin must be disassembled cleaned and sanitized • The ice machine produces ice with the cleaner and sanitizer solutions • All ice produced during the cleaning and sanitizing procedure must be discarded Procedure to Clean/Sanitize Use Ice Machine Cleaner part number 000000084.
Step 6 Fill the evaporator and reservoir with cleaning solution. Prop Float Up to Prevent Low Water Level Shutdown Step 7 Move the toggle switch to the ON position. The ice machine will make ice with the cleaning solution and deposit the ice in the bin. Add the remaining cleaner/water solution as the water level in the reservoir drops. NOTE: Do not allow the cleaner/water level to drop below the minimum water level. The ice machine will discontinue the cleaning cycle if the water float switch opens.
Step 9 Place the toggle switch in the OFF position. Step 10 Refer to disassembly for cleaning/sanitizing and remove parts for hand cleaning/sanitizing. • Hand clean all parts • Rinse all parts with clear potable water • Sanitize all parts - do not rinse after sanitizing • Spray all interior bin surfaces with sanitizer (do not rinse sanitized areas). • Spray evaporator discharge spout Step 11 Reassemble ice machine. Step 12 Turn off the ice making water supply.
Step 13 Refer to chart and premix water and sanitizer. Amount of Water Amount of Sanitizer 1 Gallons (4 L) Water 1/2 ounce (15 ml) Step 14 Fill the evaporator and reservoir with sanitizer/water solution. Step 15 Move the toggle switch to the ON position. The ice machine will make ice with the sanitizer/water solution and deposit the ice in the bin. Add the remaining sanitizer/water solution when the water level in the reservoir drops.
Heavily Scaled Cleaning Procedure Perform this procedure if you have some or all of these symptoms. • Excessive grinding, popping or squealing noises from the evaporator • Grinding noise from gearbox • Ice machine trips speed sensor NOTE: A Cleaning/Sanitizing Procedure must be performed after this procedure. Procedure to Clean Heavily Scaled Flake Ice Machines Step 1 Remove front and top covers and set the toggle switch to the OFF position. Step 2 Remove all ice from the bin.
Step 5 Refer to chart below: Premix cleaner with lukewarm water in a non-metallic container. Model Water Reservoir Capacity Mix Cleaner and Water Use Ice machine nickel safe cleaner, part number 000000084 only Cleaner Water 9 oz (266 ml) 5 oz (148 ml) 17 oz (500 ml) 11 oz (325 ml) 6 oz (177 ml) RF0244 RNS0244 RF0266 RNS0308 14 oz (400 ml) RF0385 RNS0385 RF0388 RF0399 RF0300 RF0644 RF0650 RF1200 RFS1200 34 oz (1 L) 23 oz (680 ml) 11 oz (325 ml) RF2300 RFS2300 68 oz (2 L) 46 oz (1.
REMOVAL OF PARTS FOR CLEANING/SANITIZING ! Warning Disconnect electric power to the ice machine at the electric switch box and wear rubber gloves and safety goggles (or face shield) while handling cleaner or sanitizer. ! Caution Do not mix Cleaner and Sanitizer solutions together. It is a violation of Federal law to use these solutions in a manner inconsistent with their labeling. 1. Turn off the water supply to the ice machine at the water service valve. 2.
4. Use a soft-bristle brush or sponge (NOT a wire brush) to carefully clean the parts. 5. Use the solution and a brush or sponge to clean all disassembled components and the inside of the bin. 6. Rinse all cleaned parts with clear water. 7. Mix a solution of sanitizer and water. Solution Type Water Mixed With Sanitizer 3 gal. (11 L) 2 oz (60 ml) sanitizer Part Number 94-0565-3 8. Soak the parts in the sanitizer/water solution for 10 minutes.
ICE CHUTE REMOVAL - RFS MODELS RFS0300/RF0650/RF1200/RF2300 1. Place the toggle switch in the OFF position, turn off the water supply and disconnect electrical power to the ice machine. 2. Disconnect water supply. 3. Remove water reservoir cover. 4. Remove microswitch and bin thermostat from the ice chute. 5. Remove retainer, ice chute elbow and ice chute.
Part Number 000007661 6/12 33
ICE CHUTE REMOVAL - RF MODELS RFS0300/RF0650/RF1200/RFS1200/RF2300/ RFS2300 1. Place the toggle switch in the OFF position, turn off the water supply and disconnect electrical power to the ice machine. 2. Disconnect water supply. 3. Remove water reservoir cover. 4. Remove bin thermostat from ice chute. 5. Loosen bolts holding cross member. 6. Lift cross member and remove ice chute.
ICE CHUTE SWITCH ACTUATOR REMOVAL RFS0300/RF0650/RF1200/RFS1200/RF2300/ RFS2300 1. Pull to remove nylon end cap. 2. Slide pin to remove. 3. Remove both sections of the pressure switch bracket.
RN MODELS CLEANING/SANITIZING PROCEDURE Use Ice Machine Cleaner part number 000000084. Use Ice Machine Sanitizer part number 94-0565-3. Step 1 Remove all ice from the bin/dispenser. Step 2 Remove front and top covers. Step 3 Mix a solution of cleaner and water. Amount of Luke Warm Water Amount of Cleaner Part Number 000000084 1 gallon (4 Liters) 4 ounces (120 ml) Step 4 To start a cleaning cycle, depress the CLEAN switch to drain the water from the evaporator. Wait for the LOW WATER light to energize.
Step 9 Press the OFF switch, then unscrew the ice chute connector. Step 10 Using disposable food service grade gloves insert one dry sponge into the transport tube going to the evaporator (NOT the tube going to the bin), then insert one sponge soaked in the sanitizer water solution. With the pusher tube supplied with the sponge kit, push sponges all the way down the transport tube 16 inches (41 cm) or the length of the pusher tube. Step 11 Reconnect chute connector and press the ON switch.
CLEANING THE CONDENSER ! Warning Disconnect electric power to the ice machine at the electric service switch before cleaning the condenser. The condenser fins are sharp. Use care when cleaning them. Air-Cooled Condenser Clean the condenser at least every six months. Follow the steps below. 1. Some models have a washable aluminum filter. Clean the filter with a mild soap and water solution. 2. Shine a flashlight through the condenser to check for dirt between the fins.
Removal from Service/Winterization ! Caution If water is allowed to remain in the ice machine in freezing temperatures, severe damage to some components could result. Damage of this nature is not covered by the warranty. Follow the procedure below. 1. Disconnect the electric power at the circuit breaker or the electric service switch. 2. Turn off the water supply. 3. Disconnect and drain the incoming ice-making water line at the rear of the ice machine. 4.
This Page Intentionally Left Blank 40 Part Number 000007661 6/12
Operation Ice Making Sequence of Operation NOTE: Flake ice machines use an auger to remove ice from the evaporator. Occasional noises (creaks, groans, squeaks, or pops) are a normal part of the ice making process. RF0244/RNS0244/RF0266/RF0385/RFS0385/ RNS0385/RF0388/RF0399 Self-Contained Air-Cooled When the toggle switch is placed in the “ON” position the following controls must be in the closed position before the ice machine will start: A. Bin Thermostat B. Low Evaporator Temperature Thermostat C.
RF0300/RFS0300 Self-Contained Air-Cooled When the toggle switch is placed in the “ON” position the following controls must be in the closed position before the ice machine will start: A. Bin Thermostat B. Low Evaporator Temperature Thermostat C. Ice Chute Safety Switch D. Low Water Level Switch Placing the toggle switch in the ON position starts the gear motor and a 10 minute compressor time delay. The compressor starts and the float valve controls the water inlet valve and water level.
RF0644/RF0650/RF1200/RFS1200/RF2300/ RFS2300 Self-Contained Air-Cooled When the toggle switch is placed in the ON position the following controls must be in the closed position before the ice machine will start: A. Bin Thermostat B. High Pressure Cut-out Switch C. Ice Chute Safety Switch D. Low Pressure Switch E. Low Water Level Switch Placing the toggle switch in the ON position starts the gear motor.
RF1200C/RF2300C QuietQube Remote Air-cooled Models with Remote Condensing Unit When the toggle switch is placed in the ON position the following controls must be in the closed position before the ice machine will start: A. Bin Thermostat B. High Pressure Cut-out Switch C. Ice Chute Safety Switch D. Low Pressure Switch E. Low Water Level Switch Placing the toggle switch in the ON position starts the gear motor.
RF1200C/RF2300C Head Section with Rack Refrigeration system When the toggle switch is placed in the ON position the following controls must be in the closed position before the ice machine will start: A. Bin Thermostat B. Ice Chute Safety Switch C. Low Water Level Switch Placing the toggle switch in the ON position starts the gear motor. After the rotation speed sensor verifies 10 minutes of correct rotation the time delay ends and the liquid line and suction solenoid valves energize.
RN0400 Self-Contained Air-cooled & Water-Cooled NOTE: Ice machines use an auger to remove ice from the evaporator. Occasional noises (creaks, groans, squeaks, or pops) are a normal part of the ice making process. Operation The ice machine will not start until: A. The compressor rocker switch is moved to “ON”. B. Ice does not contact the bin thermostat bulb. C. The water reservoir is full of water.
RN1000/RN1400 Self-Contained Air-Cooled & Water-Cooled NOTE: Ice machines use an auger to remove ice from the evaporator. Occasional noises (creaks, groans, squeaks, or pops) are a normal part of the ice making process. Operation The ice machine will not start until: A. The rocker switch is moved to ON. B. The transport tube shuttle switch is closed. C. The water reservoir is full of water. Placing the toggle switch in the ON position starts the gear motor and refrigeration system.
RN1000C/RN1200C QuietQube Remote Air-cooled Model with Remote Condensing Unit NOTE: Ice machines use an auger to remove ice from the evaporator. Occasional noises (creaks, groans, squeaks, or pops) are a normal part of the ice making process. Operation The ice machine will not start until: A. The rocker switch is moved to ON. B. The transport tube switch is closed. C. The water reservoir is full of water.
Ice Production/Quality Check QUALITY CHECK Ice quality varies with ambient and water temperatures, and is measured by the amount of water in the ice. Generally speaking, higher incoming water temperature results in lower ice quality. Lower water temperature results in higher ice quality. ICE PRODUCTION CHECK NOTE: Ice production checks that are within 10% of the charted capacity are considered normal due to variances in air and water temperatures. Actual temperatures will seldom match the chart exactly. 1.
Thermostat Settings Bin Thermostat: The bin thermostat sensing bulb is located in the ice chute on modular models and in the bin thermostat holder on the right side of the bin on self storage models. The bin thermostat turns the ice machine on and off as the level of ice in the bin changes. Use the initial setting from the chart and adjust as required.
Troubleshooting Electrical Flowcharts Diagnostic troubleshooting for the ice machine involves following flowcharts that are dependant on symptoms of the failed machine. Follow the flowcharts for the failure symptom and model you are working on. NOTE: Refer to the sequence of operation to determine where in the sequence the ice machine has failed. An example would be an ice machine that energizes the gear motor, but the compressor does not energize.
RF0244/RNS0244/RF0266/RF0385/RFS0385/RNS0385/RF0388/RF0399 AIR & WATER Electrical Flowchart - RF0244/RNS0244/RF0266/RF0385/RFS0385/ RNS0385/RF0388/RF0399 AIR & WATER Power Supplied to Ice Machine? NO Plug In Ice Machine, Reset Breaker NO Move Switch To ON Position YES Part Number 000007661 6/12 Toggle Switch In ON Position? YES Switch Illuminated? YES NO Replace Switch
Part Number 000007661 6/12 YES Bin Thermostat Closed? NO YES Evaporator Safety Thermostat Closed? YES NO Ice Contacting Thermostat? No Adjusting Closes Thermostat? Yes Yes Remove Ice - Allow To Warm And Retest Verify New Setting Cycles Machine On/Off Evaporator Cold? No Adjusting Closes Thermostat? Yes Yes Allow Evaporator To Warm And Retest Verify New Setting Cycles Machine On/Off No Replace Thermostat No Replace Thermostat 53
YES No Water Level Switch Closed? No Reservoir Full Of Water? NO Power To Water Inlet Valve? Yes Part Number 000007661 6/12 Yes YES Low Water Level Switch Closed? YES NO Replace Switch or Float Assembly Replace Switch or Float Assembly Repair Wiring Restore Water Supply / Replace Water Inlet Valve
Part Number 000007661 6/12 Gear Motor Runs? NO Line Voltage To Gear motor? No Yes Remove Auger From Evaporator Gear Motor Runs? No Repair Wiring Replace Gear Motor Yes YES Ice In Evaporator? Line Voltage To Compressor Relay Coil? NO Wiring From Gearmotor Intact? No YES Yes Replace Gear Motor No Repair Wiring Yes Thaw Evaporator Rebuild Evaporator 55
YES Relay Closed? NO Replace Relay NO Repair Wiring YES Line Voltage To Compressor? Part Number 000007661 6/12 YES Verify: Compressor Overload is Closed Start Components Function Fan Cycling Control Functions Condenser Fan Motor Functions Water cooled only: Water Regulating Valve Functions
Part Number 000007661 6/12 RF0300/RFS0300 AIR & WATER Electrical Flowchart – RF0300/RFS0300 Air & Water Power Supplied to Ice Machine? NO Plug In Ice Machine, Reset Breaker NO Move Switch To ON Position YES Toggle Switch In ON Position? YES Switch Illuminated? YES NO Replace Switch 57
Yes Bin Thermostat Closed? NO Yes YES Evaporator Safety Thermostat Closed? NO Part Number 000007661 6/12 NO Adjusting Closes Thermostat? Remove Ice - Allow To Warm And Retest Evaporator Cold? Ice Contacting Actuator? Yes Yes No Yes YES Chute Switch Closed? Ice Contacting Thermostat? No Allow Evaporator To Warm And Retest No Remove Ice And Retest Yes Adjusting Closes Thermostat? Yes Actuator Functions? Yes No Replace Thermostat Verify New Setting Cycles Machine On/Off No Rep
Part Number 000007661 6/12 No Replace Switch or Float Assembly YES Water Level Switch Closed? No Reservoir Full Of Water? NO YES Low Water Level Switch Closed? YES Power To Water Inlet Valve? Yes Yes NO Replace Switch or Float Assembly Repair Wiring Restore Water Supply / Replace Water Inlet Valve 59
Yes Gear Motor Runs? NO Line Voltage To Gear motor? No Yes Disconnect Evaporator From Gear Motor Gear Motor Runs? No Repair Wiring Replace Gear Motor Yes YES Part Number 000007661 6/12 Ice In Evaporator? Line Voltage To Compressor Time Delay? NO Gear Motor Centrifugal Switch Closed? Yes No Thaw Evaporator Repair Wiring No YES Yes Replace Gear Motor Rebuild Or Replace Evaporator
Part Number 000007661 6/12 Yes 10 Minute Time Delay Expired? NO Wait 10 Minutes - Do Not Install Compressor Time Delay Jumper No Repair Wiring Yes Line Voltage To Compressor Contactor Coil? Install Compressor Time NO Power To Contactor Coil? Delay Jumper YES Yes Contactor Closed? NO Replace Time Delay Relay Replace Contactor YES Repair Wiring NO Line Voltage To Compressor? YES Verify: Compressor Overload is Closed Start Components Function Fan Cycling Control Functions Condenser Fan Motor F
RF0644/RF0650/RF1200/RFS1200/RF2300/RFS2300 AIR & WATER Electrical Flowchart – RF0644/RF0650/RF1200/RFS1200 RF2300/RFS2300 AIR & WATER Power Supplied to Ice Machine? NO Plug In Ice Machine, Reset Breaker NO Move Switch To ON Position YES Part Number 000007661 6/12 Toggle Switch In ON Position? YES Switch Illuminated? YES NO Replace Switch
Part Number 000007661 6/12 Yes Bin Thermostat Closed? NO Yes YES Low Pressure Control Closed? NO YES NO No Resets? Resets & Trips Adjusting Closes Thermostat? Remove Ice - Allow To Warm And Retest Evaporator Cold? Yes YES High Pressure Control Closed? Ice Contacting Thermostat? No Refrigerant Pressure Below Cut-out? Allow Evaporator To Warm And Retest No Yes Yes Refrigerant Pressure Above Cut-out? Clean Condenser, Check Fan Motor Check Fan Cycle Control Yes No Replace Thermostat
YES Chute Switch Closed? NO Ice Contacting Actuator? No Actuator Functions? Remove Ice And Retest Yes Yes Adjust Or Replace Actuator No Replace Switch Yes Water Level Switch Closed? No Part Number 000007661 6/12 Reservoir Full Of Water? NO Power To Water Inlet Valve? Yes No Replace Switch or Float Assembly Repair Wiring YES Yes Low Water Level Switch Closed? YES NO Replace Switch or Float Assembly Restore Water Supply / Replace Water Inlet Valve
Part Number 000007661 6/12 Yes Gear Motor Runs? NO Line Voltage To Gear motor? Yes Disconnect Evaporator From Gear Motor Gear Motor Runs? No No YES Repair Wiring Ice In Evaporator? 10 Minute Time Delay Expired? NO Wait 10 Minutes - Do Not Install Compressor Time Delay Jumper No YES Replace Gear Motor Yes Yes Thaw Evaporator Rebuild Or Replace Evaporator 65
Yes Line Voltage To Compressor Contactor Coil? NO Install Compressor Time Delay Jumper Power To Contactor Coil? No Repair Wiring YES Yes Part Number 000007661 6/12 Contactor Closed? NO Replace Contactor NO Repair Wiring Replace Rotation Sensor/Time Delay Relay YES Line Voltage To Compressor? YES Verify: Compressor Overload is Closed Start Components Function Fan Cycling Control Functions Condenser Fan Motor Functions Water cooled only: Water Regulating Valve Functions
Part Number 000007661 6/12 RF1200C/RFS1200C QUIETQUBE REMOTE (OHFWULFDO )ORZFKDUW 5) & 5)6 & 4XLHW4XEH Power Supplied to Ice Machine? NO Restore Power, Reset Breaker YES Immediately Trips? YES NO YES Test Run NO Toggle Switch In ON Position? NO Move Switch To ON Position TRIPS Isolate And Ohm Each Component - Then Each Wire If Required Toggle Switch In Off Position? YES YES Switch Illuminated? YES NO Replace Switch Isolate And Ohm Switch Check Wiring From Panel 67
YES Bin Thermostat Closed? NO NO Part Number 000007661 6/12 Reservoir Full Of Water? Ice Contacting Actuator? NO NO Power To Water Inlet Valve? NO NO Actuator Functions? NO YES Water Level Switch Closed? Replace Thermostat Verify New Setting Cycles Machine On/Off YES Remove Ice And Retest YES Yes Adjusting Closes Thermostat? NO Remove Ice - Allow To Warm And Retest YES YES Chute Switch Closed? Ice Contacting Thermostat? Adjust Or Replace Actuator Replace Switch NO YES Repl
Part Number 000007661 6/12 YES Low Water Level Switch Closed? NO Replace Switch or Float Assembly Gear Motor Runs? Disconnect Evaporator From Gear Motor YES YES Gear Motor Runs? NO NO Replace Gear Motor YES Line Voltage To Gear motor? NO YES 10 Minute Time Delay Expired? Repair Wiring Ice In Evaporator? Wait 10 Minutes - Do Not Install Compressor Time Delay Jumper NO YES NO YES Thaw Evaporator Rebuild Or Replace Evaporator 69
YES Line Voltage To Left Delay Relay Coil? NO Part Number 000007661 6/12 Install Compressor Time Delay Jumper On Left Evaporator YES Delay Relay Contacts Closed? Power To Left Time Delay Relay Coil? NO Repair Wiring Yes NO Replace Relay Delay Relay Contacts Closed? NO YES Replace Relay YES Replace Rotation Sensor/Time Delay
Part Number 000007661 6/12 YES High Pressure Control Closed? NO NO Line Voltage To Compressor Contactor Coil? Resets? NO NO Replace HPCO Resets & Trips YES Refrigerant Pressure Above Cut-out? YES Clean Condenser, Check Fan Motor Check Fan Cycle Control NO Clean Condenser, Check Fan Motor, Check Fan Cycle Control & Refrigeration System Replace Relay Low Pressure Control Closed? NO YES YES Repair Wiring Verify: Refrigerant Pressure is Higher Than LPCO Cut-in Both Shut-off Valves are Open Re
YES Contactor Closed? NO Replace Contactor Part Number 000007661 6/12 YES Line Voltage To Compressor? NO Repair Wiring YES Verify: Compressor Overload is Closed Start Components Function Fan Cycling Control Functions Condenser Fan Motor Functions
Part Number 000007661 6/12 RF2300/RFS2300C AIR & WATER Electrical Flowchart – RF2300 5)6 & Air & Water Power Supplied to Ice Machine? NO No NO Move Switch To ON Position YES Trips Yes Toggle Switch In Off Position? Isolate And Ohm Each Component - Then Each Wire If Required Yes Ohm Compressor Crankcase Heater And Toggle Switch YES Switch Illuminated? Immediately Trips? No Yes Toggle Switch In ON Position? Restore Power, Reset Breaker NO Replace Switch 73
Yes Bin Thermostat Closed? NO YES High Pressure Control Closed? NO Part Number 000007661 6/12 Yes NO Adjusting Closes Thermostat? No Yes Remove Ice - Allow To Warm And Retest Resets? No Resets & Trips YES Left Side Chute Switch Closed? Ice Contacting Thermostat? Ice Contacting Actuator? Yes Yes Refrigerant Pressure Above Cut-out? Clean Condenser, Check Fan Motor Check Fan Cycle Control No Remove Ice And Retest Yes Actuator Functions? Yes No Replace Thermostat Verify New Sett
Part Number 000007661 6/12 YES Right Side Chute Switch Closed? NO Ice Contacting Actuator? NO Actuator Functions? Remove Ice And Retest Yes Low Pressure Control Closed? No Evaporator Cold? No Yes Refrigerant Pressure Below Cut-out? Allow Evaporator To Warm And Retest Yes Yes Adjust Or Replace Actuator No Replace Switch No Replace LPCO Repair Refrigerant Leak, Evacuate, Recharge Yes Water Level Switch Closed? No Reservoir Full Of Water? YES NO Power To Water Inlet Valve? Yes Yes
Yes Low Water Level Switch Closed? NO Replace Switch or Float Assembly YES Gear Motor Runs? NO Line Voltage To Gear motor? Part Number 000007661 6/12 No Yes Repair Wiring Disconnect Evaporator From Gear Motor Gear Motor Runs? No Replace Gear Motor Yes YES Ice In Evaporator? 10 Minute Time Delay Expired? NO Wait 10 Minutes - Do Not Install Compressor Time Delay Jumper No YES Yes Thaw Evaporator Rebuild Or Replace Evaporator
Part Number 000007661 6/12 YES Line Voltage To Left Delay Relay Coil? NO Install Compressor Time Delay Jumper On Left Evaporator Power To Left Time Delay Relay Coil? YES Left Delay Relay Contacts Closed? No Repair Wiring Yes NO Replace Relay No Left Delay Relay Contacts Closed? Yes Power To Right Time Delay Relay Coil? No Replace Left Rotation Sensor/Time Delay YES Line Voltage To Right Delay Relay Coil? NO Install Compressor Time Delay Jumper On Right Evaporator Yes YES Right Delay
Yes Line Voltage To Compressor Contactor Coil? NO Repair Wiring YES Contactor Closed? Part Number 000007661 6/12 NO Replace Contactor NO Repair Wiring YES Line Voltage To Compressor? YES Verify: Compressor Overload is Closed Start Components Function Fan Cycling Control Functions Condenser Fan Motor Functions Water cooled only: Water Regulating Valve Functions
Part Number 000007661 6/12 RF2300C/RFS2300C QUIETQUBE REMOTE (OHFWULFDO )ORZFKDUW 5) & 5)6 & 4XLHW4XEH Power Supplied to Ice Machine? NO Restore Power, Reset Breaker YES Immediately Trips? YES NO YES Test Run NO Toggle Switch In Off Position? Toggle Switch In ON Position? NO Move Switch To ON Position YES Switch Illuminated? YES TRIPS Isolate And Ohm Each Component - Then Each Wire If Required YES Isolate And Ohm Switch Check Wiring From Panel NO Replace Switch 79
YES Bin Thermostat Closed? NO YES Left Side Chute Switch Closed? NO Part Number 000007661 6/12 YES NO Adjusting Closes Thermostat? NO YES Remove Ice - Allow To Warm And Retest Ice Contacting Actuator? NO YES YES Right Side Chute Switch Closed? Ice Contacting Thermostat? Ice Contacting Actuator? YES Remove Ice And Retest NO Remove Ice And Retest YES Actuator Functions? YES Actuator Functions? YES NO Replace Thermostat Verify New Setting Cycles Machine On/Off Adjust Or Replac
Part Number 000007661 6/12 YES Reservoir Full Of Water? NO Power To Water Inlet Valve? YES Low Water Level Switch Closed? Water Level Switch Closed? NO YES Restore Water Supply / Replace Water Inlet Valve YES NO NO Replace Switch or Float Assembly Repair Wiring Gear Motor Runs? NO Replace Switch or Float Assembly Replace Gear Motor YES Disconnect Evaporator From Gear Motor YES YES Do Both Gear Motors Run? NO Line Voltage To Gear motors? Ice In Evaporator? YES NO YES NO Repair Wiring
Yes 10 Minute Time Delay Expired? NO Wait 10 Minutes - Do Not Install Compressor Time Delay Jumper YES Part Number 000007661 6/12 Line Voltage To Left Delay Relay Coil? NO Install Compressor Time Delay Jumper On Left Evaporator Power To Left Time Delay Relay Coil? YES Left Delay Relay Contacts Closed? YES No Repair Wiring Yes NO Replace Relay No Left Delay Relay Contacts Closed? Yes Replace Left Rotation Sensor/Time Delay
Part Number 000007661 6/12 YES Line Voltage To Right Delay Relay Coil? NO Install Compressor Time Delay Jumper On Repair Wiring Power To Right Time Delay Relay Coil? NO Right Evaporator YES YES Right Delay Relay Contacts Closed? YES NO Right Delay Relay Contacts Closed? YES NO Replace Right Rotation Sensor/Time Delay Replace Relay Replace Relay 83
High Pressure Control Closed? YES NO Resets? Refrigerant Pressure Above Cut-out? NO Replace HPCO NO Line Voltage To Compressor Contactor Coil? NO Resets & Trips YES YES Clean Condenser, Check Fan Motor, Check Fan Cycle Control & Refrigeration System Clean Condenser, Check Fan Motor Check Fan Cycle Control Part Number 000007661 6/12 NO Low Pressure Control Closed? NO YES Line Voltage At Liquid Line Solenoid Valve? YES Repair Wiring YES Replace Relay Verify: Refrigerant Pressure is Hi
Part Number 000007661 6/12 YES Contactor Closed? NO Replace Contactor YES Line Voltage To Compressor? NO Repair Wiring YES Verify: Compressor Overload is Closed Start Components Function Fan Cycling Control Functions Condenser Fan Motor Functions 85
RN0400 AIR & WATER Electrical Flowchart – RN0400 Control Board PWR Light On? NO Power Supplied to Ice Machine Control board? YES Part Number 000007661 6/12 Bin Empty (BE) Light On? NO YES NO Plug In Ice Machine, Reset Breaker Replace Control Board Bin Thermostat Closed? YES NO YES Ice Contacting Thermostat? Yes No Remove Ice - Allow To Warm And Retest Adjusting Closes Thermostat? Yes No Replace Thermostat Verify New Setting Cycles Machine On/Off
Part Number 000007661 6/12 Yes Time Delay (BT) Light Off? NO YES Water Supply OK? NO Water (WTR) Light On? 20 Minute Time Delay Period – Depress Control Board Reset Button To Override Delay Period No Supply Water To Ice Machine Yes Reservoir Full? NO Line Voltage To Water Inlet Valve? YES Replace Water Inlet Valve NO YES YES Disconnect Probes & Jumper Sensor Inputs On Control Board WTR Light On WTR Light Off Clean, Repair, Or Replace Water Level Probe Assembly Replace Control Board 8
YES WTR Light Flashing? YES BT Light On? NO YES 20 Minute Time Delay Period Depress Control Board Reset Button To Override Delay Period Press Control Board Reset Button – Flashing Stops, Gear Motor And Yes Determine Cause Of Water Loss Compressor Energize NO No Part Number 000007661 6/12 NO Compressor (C) Light On? YES NO Compressor Switch In On Position? YES Move Switch To On Position Next Disconnect Switch From Control Board Disconnect/Reconnect Power, Replace Control Board If Ice
Part Number 000007661 6/12 Yes Line Voltage @ Control Board Compressor And Fan Terminals? NO or Only One Component Has Line Voltage Verify: Clearances & Ambient Are OK Filter & Condenser Are Clean Condenser Fan Motor Functions Water cooled Models: Water Regulating Valve Functions Reset Or Replace High Pressure Cut Out YES HPCO Closed? NO YES Line Voltage To Compressor? NO Repair Wiring NO Verify: Compressor Overload is Closed Start Components Function Compressor Windings Are OK YES Compressor R
YES Yes Gear Motor Runs? NO Lights on? 20M Light On? YES YES 2nd Light On? 20 Minute Time Delay Period - Verify No Ice In Evaporator Depress Control Board Reset Button To Override Delay Period Perform Heavily Scaled Cleaning Procedure YES Locked Out Due To Over Torque Condition Verify No Ice In Evaporator Depress Control Board Reset Button Perform Heavily Scaled Cleaning Procedure YES/NO YES DR or No Lights On? Part Number 000007661 6/12 60M Light On? Ice Machine Experienced Over Torque Co
Part Number 000007661 6/12 RN1000/RN1400 AIR & WATER Electrical Flowchart – RN1000 51 Air & Water Control Board CPU Light Flashing? Rocker Switch in ON position? NO YES Control Board PWR Light On? NO YES NO Power Supplied to Ice Machine Control board? NO YES YES Turn On Switch Remove & Restore Line Voltage, Then Depress Reset Button On Control Board Plug In Ice Machine, Reset Breaker Replace Control Board Power Light Off Power Light On Test Run & Verify Operation 91
Yes Time Delay Light OFF? NO YES Low Bin Light On? Time Delay Period Expired? NO Wait For Delay To Expire YES NO Shuttle in up position? Light On Sensor Illuminated? NO Part Number 000007661 6/12 YES YES Ice Holding Shuttle Open? NO Clear Ice Check Wiring, Repair Or Replace Depress Reset Button On Control Board Replace Control Board If Required Repair Or Replace Shuttle YES YES NO
Part Number 000007661 6/12 YES Purge Light Off? NO Purge Rocker Switch In Off Position? NO Move Switch To Off Position YES Line Voltage At Drain Solenoid? Remove & Restore Line Voltage, Then Depress Reset Button On Control Board No No Power @ Solenoid Replace Control Board YES YES Power @ Solenoid Water Drains From Evaporator? NO Clear Drain Or Replace Drain Solenoid NO Level Ice Machine To Allow Complete Drainage YES Ice Machine Level? YES Test Run To Verify Operation 93
YES Drain Clog Light Off? NO Water In Drain Trough? YES Clear Drain NO Clean and Dry Drain Sensor Disconnect Sensor From Control Board Light On YES Light Off Part Number 000007661 6/12 Light Off High Pressure Light Off? YES Light On NO Replace Control Board Replace Sensor Test Run To Verify Operation Verify: Clearances & Ambient Are OK Filter & Condenser Are Clean Condenser Fan Motor Functions Replace High Pressure Cut Out Water cooled Models: Water Regulating Valve Functions YES Pres
Part Number 000007661 6/12 Yes HI AMPS Light Off? NO Circuit Breaker On Control Box Tripped? YES Reset Breaker - Press Control Board Reset Button To Clear Error NO Line Voltage To Gear Motor? Press Control Board Reset Button To Clear Error NO YES YES Gear Motor Runs? NO YES Clean Ice Machine - Install Water Filter - Increase Cleaning Frequency -Verify Shuttle Shuts Off Ice Machine – Test Run Check Wires & Connections Replace Gear Motor NO Replace Control Board 95
Yes Low Water Light Off? NO Sensor Wires Connected? NO Connect Sensor Wires YES Reservoir Full Of Water? NO Water is Supplied? Part Number 000007661 6/12 YES Restore Water Supply YES Replace Water Inlet Valve YES YES Clean and Dry Water Level Probes NO Voltage @ Water Inlet Valve? NO YES Voltage @ Water Inlet Valve? NO YES Replace Control Board Reservoir Full Of Water? YES NO Press Control Board Reset Button To Clear Error
Part Number 000007661 6/12 Yes High Water Light Off? NO Control Board Sending Line Voltage To Water Valve? NO Press Control Board Reset Button Replace Control Board YES Voltage @ Water Inlet Valve? NO Replace Water Inlet Valve YES YES Clean, Dry & Reinsert Water Level Probes Water Flows Water Flow Stops Gear Motor Running? YES NO See Step HI AMPS LIGHT OFF Replace Sensor – Control Board if Required Press Control Board Reset Button To Clear Error 97
Yes Compressor Running? NO Line Voltage @ Control Board Compressor Terminals NO Replace Control Board YES Line Voltage At Compressor? NO Repair Wiring YES Part Number 000007661 6/12 YES Compressor Running? NO Verify: Compressor Overload is Closed Start Components Function Compressor Windings Are OK YES Ice Has Excessive Water Content? YES NO Test Run To Verify Operation Verify Water Inlet Valve Closes 100% & Water Level Probe Functions
Part Number 000007661 6/12 RN1000C/RN1200C QUIETQUBE REMOTE Electrical FlowcKart – RN1000& 51 & QuietQube Remote Control Board CPU Light Flashing? Rocker Switch in ON position? NO YES Control Board PWR Light On? NO YES NO Power Supplied to Ice Machine Control board? NO YES YES Turn On Switch Remove & Restore Line Voltage, Then Depress Reset Button On Control Board Power Light On Plug In Ice Machine, Reset Breaker Replace Control Board Power Light Off Test Run & Verify Operation 99
Yes Time Delay Light OFF? NO YES Low Bin Light On? Time Delay Period Expired? NO Wait For Delay To Expire YES NO Shuttle in up position? Light On Sensor Illuminated? NO Part Number 000007661 6/12 YES YES Ice Holding Shuttle Open? NO Clear Ice Check Wiring, Repair Or Replace Depress Reset Button On Control Board Replace Control Board If Required Repair Or Replace Shuttle YES YES NO
Part Number 000007661 6/12 YES Purge Light Off? NO Purge Rocker Switch In Off Position? NO Move Switch To Off Position YES Line Voltage At Drain Solenoid? Remove & Restore Line Voltage, Then Depress Reset Button On Control Board No No Power @ Solenoid Replace Control Board YES YES Power @ Solenoid Water Drains From Evaporator? NO Clear Drain Or Replace Drain Solenoid NO Level Ice Machine To Allow Complete Drainage YES Ice Machine Level? 101 YES Test Run To Verify Operation
YES Drain Clog Light Off? NO Water In Drain Trough? YES Clear Drain NO Clean and Dry Drain Sensor Light On YES Part Number 000007661 6/12 YES Light On Light Off Light Off High Pressure Light Off? Disconnect Sensor From Control Board NO Verify: Clearances & Ambient Are OK Condenser Is Clean Condenser Fan Motor Functions Replace High Pressure Cut Out Replace Control Board Replace Sensor Test Run To Verify Operation YES Press Control Board Reset Button To Clear Error
Part Number 000007661 6/12 YES HI AMPS Light Off? NO Circuit Breaker On Control Box Tripped? YES Reset Breaker - Press Control Board Reset Button To Clear Error NO Line Voltage To Gear Motor? Press Control Board Reset Button To Clear Error NO YES YES Gear Motor Runs? NO YES Clean Ice Machine - Install Water Filter - Increase Cleaning Frequency -Verify Shuttle Shuts Off Ice Machine – Test Run Check Wires & Connections Replace Gear Motor NO Replace Control Board 103
YES Low Water Light Off? NO Sensor Wires Connected? NO Connect Sensor Wires YES Reservoir Full Of Water? NO Water is Supplied? Part Number 000007661 6/12 YES Restore Water Supply YES Replace Water Inlet Valve YES YES Clean and Dry Water Level Probes NO Voltage @ Water Inlet Valve? NO YES Voltage @ Water Inlet Valve? NO YES Replace Control Board Reservoir Full Of Water? YES NO Press Control Board Reset Button To Clear Error
Part Number 000007661 6/12 YES High Water Light Off? NO Control Board Sending Line Voltage To Water Valve? NO Press Control Board Reset Button Replace Control Board YES Voltage @ Water Inlet Valve? NO Replace Water Inlet Valve YES YES Clean, Dry & Reinsert Water Level Probes Water Flows Water Flow Stops Gear Motor Running? 105 YES NO See Step HI AMPS LIGHT OFF Replace Sensor – Control Board if Required Press Control Board Reset Button To Clear Error
YES Compressor Running? NO Line Voltage @ Control Board Compressor Terminals NO Replace Control Board YES Part Number 000007661 6/12 Line Voltage At Liquid Line Solenoid Valve? NO YES YES Low Pressure Control Closed? YES NO Repair Wiring Verify: Refrigerant Pressure is Higher Than LPCO Cut-in Both Shut-off Valves are Open Repair/Replace Liquid Line Solenoid Locate and Repair Refrigerant Leak Replace LPCO Switch
Part Number 000007661 6/12 YES Contactor Coil Has Line Voltage? NO Repair Wiring YES Contactor Closed? YES NO Replace Contactor NO Repair Wiring YES Line Voltage At Compressor? YES Compressor Running? NO YES Verify: Compressor Overload is Closed Start Components Function Compressor Windings Are OK Test Run To Verify Operation 107
YES Ice Has Excessive Water Content? YES NO Test Run To Verify Operation Verify Water Inlet Valve Closes 100% & Water Level Probe Functions Part Number 000007661 6/12
Part Number 000007661 6/12 Refrigeration Troubleshooting CAPILLARY TUBE MODELS If the gear motor and/or compressor are not energized refer to Electrical Troubleshooting Refer to Operational Pressure Charts for normal pressures and temperatures Low on Refrigerant Overcharge of Refrigerant Non Condensable in System Restricted Capillary Tube Discharge Pressure Low High High Low Suction Pressure Low High High Low Evaporator Inlet Temperature Normal Low High Low Evaporator Outlet Temperature
THERMOSTATIC EXPANSION VALVE MODELS If the gear motor and/or compressor are not energized refer to Electrical Troubleshooting Refer to Operational Pressure Charts for normal pressures and temperatures Low on Refrigerant Overcharge of Refrigerant Non Condensable In System Liquid Line Restriction, Suction Line Restriction, Or TXV Starving Flooding TXV or Loose Sensing Bulb Discharge Pressure Low High High Low High Suction Pressure Part Number 000007661 6/12 Low High High Low High Evapora
Component Specifications BIN THERMOSTAT Model RF0244/RNS0244 RF0266/RNS0308 RF0385/RNS0385 RF0388/RF0399 RF0644/RF1200 RFS1200/RF2300 RF0300/RFS0300 RF0650 Setting Cut-Out Cut-In 5 37°F ±1 3°C ±.1 43°F ±1 6°C ±.1 4 36°F ±1 2.2°C ±.1 42°F ±1 5.6°C ±.1 LOW TEMPERATURE THERMOSTAT Evaporator safety thermostat) Model RF0244/RNS0244 RF0266 RF1200/RFS1200 RF2300/RFS2300 RF0300/RFS0300 RF0385/RNS0385 RF0388/RF0399 RF0644/RF650 Setting Cut-Out Cut-In 5 -9°F ±1 -23°C ±.1 10°F ±1 -12°C ±.1 7 -11°F ±.
HIGH PRESSURE CUTOUT (HPCO) CONTROL Model Cut-Out Cut-In 435 psig ±10 RF0650/ (3000 kPa ±69) Manual Reset RF1200/RF2300 30 bar ±.69 287 psig ±10 425 psig ±10 (1979 kPa ±69) RN0400/RN1000/RN1400 (2930 kPa ±69) 19.79bar ±.69 29 bar ±.69 Auto Reset 295 psig ±10 RN1000C/RCU1075 450 psig ±10 (2034 kPa ±69) RN1200C/RCU1275 (3100 kPa ±69) 20 bar ±.69 RF1200C/RCU1075 31 bar ±.69 Auto Reset 450 psig ±10 RF2300C/RCU2375 (3100 kPa ±69) Manual Reset 31 bar ±.
LOW PRESSURE CUTOUT (LPCO) CONTROL Model R0F650/ RF1200 Cut-Out 7 psig ±2 (.5 bar ±.2) 12 psig ±2 (.8 bar ±.2) RF2300 RN1000C/RCU1075 RN1200C/RCU1275 RF1200C/RCU1075 RFS1200C/RCU1075 RF2300C/RCU2375 RFS2300C/RCU2375 12 psig ±3 (.8 bar ±.2) Cut-In 36 psig ±2 (2.5 bar ±.2) Manual Reset 35 psig ±5 (2.4 bar ±.4) FAN CYCLE CONTROL Model RF0244 RF0266 RF0385 RF0388 RF0399 RF0300 60 hz RF0300 50 hz RF0650 60 hz RF0650 50 hz RF1200 60 hz RF1200 50 hz RF2300 Cut-Out (Open) 230 ±5 (16 bar ±.
FILTER-DRIERS The size of the filter-drier is important. The refrigerant charge is critical. Using an improperly sized filter-drier will cause the ice machine to be improperly charged with refrigerant. Important Driers are covered as a warranty part. The drier must be replaced any time the system is opened for repairs. SUCTION CLEANUP FILTER-DRIER Contaminated systems must have a suction line filterdrier installed to remove contamination.
TOTAL SYSTEM REFRIGERANT CHARGE Important This information is for reference only. Refer to the ice machine serial number tag to verify the system charge. Serial plate information overrides information listed on this page. Model Refrigerant Charge RF0244A 7.5 oz / 210 g RNS0244A 7.5 oz / 210 g RF0266A 7.5 oz / 210 g RF0300A/RFS0300A 11.25 oz / 320 g RF0385A 11.25 oz / 320 g RNS0385A 11.25 oz / 320 g RF0388A 11.25 oz / 320 g RF0399A 11.25 oz / 320 g RN0400 19 oz / 539 g RF0650A 19.
This Page Intentionally Left Blank 116 Part Number 000007661 6/12
Charts Ice Production & Refrigerant Pressure These charts are used as guidelines to verify correct ice machine operation. Accurate collection of data is essential to obtain the correct diagnosis. • Zero out manifold gauge set before obtaining pressure readings to avoid misdiagnosis. • Discharge and suction pressure are highest at the beginning of the cycle. Allow system to stabilize for a minimum of 10 minutes, then verify the pressures are within the range indicated.
Flake Models RF0244A & RFS0244 SELF STORAGE AIR-COOLED Characteristics vary depending on operating conditions.
RF0266A SELF STORAGE AIR-COOLED Characteristics vary depending on operating conditions.
RF0300A & RFS0300A SELF CONTAINED AIR-COOLED Characteristics vary depending on operating conditions.
RF0385A SELF STORAGE AIR-COOLED Characteristics vary depending on operating conditions.
RF0388A SELF STORAGE AIR-COOLED Characteristics vary depending on operating conditions.
RF0399A SELF STORAGE AIR-COOLED Characteristics vary depending on operating conditions.
RF0644A AIR-COOLED Characteristics vary depending on operating conditions.
RF0650A AIR-COOLED Characteristics vary depending on operating conditions.
RF0650W WATER-COOLED Characteristics vary depending on operating conditions.
RF1200A & RFS1200A AIR-COOLED Characteristics vary depending on operating conditions.
RF1200W & RFS1200W WATER-COOLED Characteristics vary depending on operating conditions.
RF1278C & RFS1278C QUIETQUBE REMOTE AIR COOLED Characteristics vary depending on operating conditions ICE PRODUCTION Air Temperature Water Temperature 24 Hour Ice Production -20°F/50°F -29°C/10°C 1413 lbs 641 kg 70°F/50°F 21°C/10°C 1182 lbs 536 kg 90°F/70°F 32°C/21°C 975 442 kg 120°F/70°F 49°C/21°C 603 274 kg OPERATING PRESSURES PSIG/kPa Freeze Cycle Air Temperature Entering Condenser °F/°C Discharge Pressure Suction Pressure 50°F PSIG 10°C kPa 185-200 1276-1379 23-28 159-193 70°F PSIG 21°C
RF2300A AIR-COOLED Characteristics vary depending on operating conditions.
RF2300W WATER-COOLED Characteristics vary depending on operating conditions.
RF2378C & RFS2378C QUIETQUBE REMOTE AIR COOLED Characteristics vary depending on operating conditions ICE PRODUCTION Air Temperature Water Temperature 24 Hour Ice Production -20°F/50°F -29°C/10°C 2448 lbs 1110 kg 70°F/50°F 21°C/10°C 2137 lbs 969 kg 90°F/70°F 32°C/21°C 1748 lbs 793 kg 120°F/70°F 49°C/21°C 1118 lbs 507 kg OPERATING PRESSURES PSIG/kPa Freeze Cycle Air Temperature Around Ice Machine °F/°C Discharge Pressure Suction Pressure 50°F PSIG 16°C kPa 175-200 1207-1379 26-31 176-214 70°
Nugget Models RNS0244A SELF STORAGE AIR-COOLED Characteristics vary depending on operating conditions.
RNS0385A SELF STORAGE AIR-COOLED Characteristics vary depending on operating conditions.
RN0400A AIR-COOLED Characteristics vary depending on operating conditions ICE PRODUCTION Air Temperature Water Temperature 24 Hour Ice Production 70°F/50°F 21°C/10°C 385 lbs 175 kg 90°F/70°F 32°C/21°C 294 lbs 133 kg OPERATING PRESSURES PSIG/kPa Freeze Cycle Air Temperature Around Ice Machine °F/°C Discharge Pressure Suction Pressure 60°F PSIG 16°C kPa 170-200 1172-1379 23-25 159-172 70°F PSIG 21°C kPa 240-270 1655-1862 25-30 172-207 80°F PSIG 27°C kPa 245-275 1689-1896 30-35 207-241 90°F
RN1000A AIR-COOLED Characteristics vary depending on operating conditions 24-HOUR ICE PRODUCTION IN LB/KG Air Temperature Entering Condenser °F/°C Water Temperature °F/°C 50/10 60/16 70/21 80/27 90/32 60°F 16°C 1135 515 1070 486 1015 461 967 439 924 420 70°F 21°C 1100 499 1000 454 938 426 902 410 859 390 80°F 27°C 962 437 916 416 871 395 826 375 782 355 90°F 32°C 828 376 816 371 794 361 755 343 698 317 100°F 38°C 786 357 728 331 686 312 654 297 610 277 OPERATING PRESSURES
RN1000W WATER-COOLED Characteristics vary depending on operating conditions 24-HOUR ICE PRODUCTION IN LB/KG Air Temperature Around Ice Machine °F/°C Water Temperature °F/°C 50/10 60/16 70/21 80/27 90/32 60°F 16°C 1071 486 1025 465 971 441 912 414 849 386 70°F 21°C 1035 470 979 444 932 423 888 403 842 382 80°F 27°C 975 443 912 414 870 395 839 381 814 370 90°F 32°C 885 402 826 375 786 357 759 345 745 338 100°F 38°C 762 346 723 328 683 310 642 392 603 274 OPERATING PRESSURES
RN1400A AIR-COOLED Characteristics vary depending on operating conditions ICE PRODUCTION Air Temperature Water Temperature 24 Hour Ice Production 50°F/50°F 10°C/10°C 1462 lbs 663 kg 70°F/50°F 21°C/10°C 1456 lbs 660 kg 90°F/70°F 32°C/21°C 1100 lbs 499 kg 110°F/70°F 43°C/21°C 801 lbs 363 kg OPERATING PRESSURES PSIG/kPa Freeze Cycle Air Temperature Around Ice Machine °F/°C Discharge Pressure Suction Pressure 50°F PSIG 10°C kPa 224-235 1544-1620 24-29 165-200 70°F PSIG 21°C kPa 238-275 1641-18
RN1400W WATER-COOLED Characteristics vary depending on operating conditions ICE PRODUCTION Air Temperature Water Temperature 24 Hour Ice Production 50°F/50°F 10°C/10°C 1606 lbs 728 kg 70°F/50°F 21°C/10°C 1514 lbs 687 kg 90°F/70°F 32°C/21°C 1100 lbs 499 kg 110°F/70°F 43°C/21°C 1151 lbs 522 kg OPERATING PRESSURES PSIG/kPa Freeze Cycle Air Temperature Around Ice Machine °F/°C Discharge Pressure Suction Pressure 50°F PSIG 10°C kPa 220-230 1516-1586 24-29 165-200 70°F PSIG 21°C kPa 220-230 1517
RN1078C QUIETQUBE REMOTE AIR COOLED Characteristics vary depending on operating conditions ICE PRODUCTION Air Temperature Water Temperature 24 Hour Ice Production -20°F/50°F -29°C/10°C 1120 lbs 508kg 70°F/50°F 21°C/10°C 898 lbs 407kg 90°F/70°F 32°C/21°C 770 lbs 349kg 120°F/70°F 49°C/21°C 490 lbs 222kg OPERATING PRESSURES PSIG/kPa Freeze Cycle Air Temperature Around Ice Machine °F/°C Discharge Pressure Suction Pressure 60°F PSIG 16°C kPa 240-250 1655-1724 33-35 227-241 70°F PSIG 21°C kPa 24
RN1278C QUIETQUBE REMOTE AIR COOLED Characteristics vary depending on operating conditions ICE PRODUCTION Air Temperature Water Temperature 24 Hour Ice Production -20°F/50°F -29°C/10°C 1201 lbs 545kg 70°F/50°F 21°C/10°C 981 lbs 445kg 90°F/70°F 32°C/21°C 770 lbs 349kg 120°F/70°F 49°C/21°C 681 lbs 309kg OPERATING PRESSURES PSIG/kPa Freeze Cycle Air Temperature Around Ice Machine °F/°C Discharge Pressure Suction Pressure 50°F PSIG 10°C kPa 190-200 1310-1379 21-26 145-179 70°F PSIG 21°C kPa 22
Rack Models RF1279R QUIETQUBE REMOTE AIR COOLED Characteristics vary depending on operating conditions 24-HOUR ICE PRODUCTION IN LB/KG Water Temperature °F/°C 50/10 1413 lbs 641 kg SUCTION PRESSUREPSIG/kPa Freeze Cycle Liquid Line Pressure Acceptable Suction Pressure Range 185-200 psi 1276-1379 kPa 23-28 psi 159-193 kPa 225-255 psi 1551-1758 kPa 30-35 psi 207-241 kPa 230-280 psi 1586-1931 kPa 31-36 psi 214-248 kPa 243-305 psi 1675-2103 kPa 33-38 psi 228-262 kPa 355-400 psi 2448-2758 kPa 38-43 ps
RF2379R QUIETQUBE REMOTE AIR COOLED Characteristics vary depending on operating conditions 24-HOUR ICE PRODUCTION IN LB/KG Water Temperature °F/°C 50/10 2448 lbs 1110 kg SUCTION PRESSUREPSIG/kPa Freeze Cycle Liquid Line Pressure Acceptable Suction Pressure Range 175-200 psi 1207-1379 kPa 26-31 psi 176-214 kPa 220-250 psi 1517-1724 kPa 31-36 psi 214-248 kPa 225-275 psi 1551-1896 kPa 32-37 psi 221-255 kPa 250-310 psi 1724-2137 kPa 33-38 psi 228-262 kPa 365-410 psi 2517-2827 kPa 38-43 psi 262-296 k
This Page Intentionally Left Blank 144 Part Number 000007661 6/12
Diagrams Wiring Diagrams The following pages contain electrical wiring diagrams. Be sure you are referring to the correct diagram for the ice machine you are servicing. ! Warning Always disconnect power before working on electrical circuitry.
Flake Models RF0244/RNS0244/RF0266/RF0385/RNS0385/ RF0388/RF0399 AIR-COOLED Refer to Nameplate for Voltage Rating 146 Part Number 000007661 6/12
WIRING DIAGRAM LEGEND RF0244/RNS0244/RF266/RF0385/RNS0385/RF0388/ RF0399 1 Gear Motor 2 Compressor 4 Condenser fan motor 6 Water Inlet valve 7 Evaporator low temperature safety 10 Low water level safety 11 Bin thermostat 12 High temperature limit (snap disc) 13 Fan cycle control 17 Water level switch 21 Compressor relay 24 On/Off switch 26 Gear motor centrifugal switch Wire Color Designation B White BL Blue G Grey M Brown N Black R Red RS Pink Part Number 000007661 6/
RF0300/RFS0300 AIR-COOLED Refer to Nameplate for Voltage Rating 148 Part Number 000007661 6/12
WIRING DIAGRAM LEGEND RF0300/RFS0300 1 Gear Motor 2 Compressor 4 Condenser fan motor 6 Water inlet valve 7 Evaporator low temperature safety 10 Low water level safety 11 Bin thermostat 13 Fan cycle control 17 Water level switch 18 Ice chute safety switch 21 Compressor relay 24 On/Off switch 25 Compressor time delay 26 Gear motor centrifugal switch 35 Compressor time delay by-pass Wire Color Designation B White BL Blue G Grey M Brown N Black R Red RS Pink Part Numb
RF0650/RF1200/RFS1200 AIR-COOLED Refer to Nameplate for Voltage Rating 150 Part Number 000007661 6/12
WIRING DIAGRAM LEGEND RF0650/RF1200/ RFS1200 1 Gear Motor 2 Compressor 4 Condenser fan motor 6 Water inlet valve 10 Low water level safety 11 Bin thermostat 13 Fan cycle control 15 Contactor 17 Water level switch 18 Ice chute safety switch 19 High pressure cut out 21 Compressor relay 24 On/Off switch 25 Compressor time delay 27 Low pressure cut out 30 Rotation sensor 35 Compressor time delay by-pass Wire Color Designation B White BL Blue G Grey M Brown N Black R
RF1200/RFS1200 WATER-COOLED Refer to Nameplate for Voltage Rating 152 Part Number 000007661 6/12
WIRING DIAGRAM LEGEND RF1200/RFS1200 WATER-COOLED 1 Gear Motor 2 Compressor 4 Condenser fan motor 6 Water inlet valve 10 Low water level safety 11 Bin thermostat 13 Fan cycle control 15 Contactor 17 Water level switch 18 Ice chute safety switch 19 High pressure cut out 21 Compressor relay 24 On/Off switch 25 Compressor time delay 27 Low pressure cut out 30 Rotation sensor 35 Compressor time delay by-pass Wire Color Designation B White BL Blue G Grey M Brown N Black
RF1200C/RFS1200C QUIETQUBE HEAD SECTION To Remote Panel Remove Jumper when used Supply Power To RCU Condensing Unit 154 Part Number 000007661 6/12
WIRING DIAGRAM LEGEND RF1200C/RFS1200C 1 Gear Motor 6 Water inlet valve 10 Low water level safety 11 Bin thermostat 17 Water level switch 18 Ice chute safety switch 21 Compressor Relay 24 On/Off switch 30 Rotation sensor 35 Compressor time delay by-pass 38 Solenoid Valve Wire Color Designation B White BL Blue G Grey M Brown N Black R Red V Violet A Orange Part Number 000007661 6/12 155
RF2300/RFS2300 AIR-COOLED & WATERCOOLED Refer to Nameplate for Voltage Rating 156 Part Number 000007661 6/12
WIRING DIAGRAM LEGEND RF2300/RFS2300 AIR & WATER COOLED 1 Gear Motor 2 Compressor 4 Condenser fan motor (air-cooled only) 6 Water inlet valve 10 Low water level safety 11 Bin thermostat 13 Fan cycle control 15 Contactor 17 Water level switch 18 Ice chute safety switch 19 High pressure cut out 24 On/Off switch 25 Compressor time delay 27 Low pressure cut out 29 Compressor time delay relay 30 Rotation sensor 35 Compressor time delay by-pass 37 Remote indicator panel terminal
To Refrigerating Plant Power Supply To Remote Electrical Panel (Remove Bypass) RF2378C/RFS2378C QUIETQUBE HEAD SECTION Part Number 000007661 6/12
WIRING DIAGRAM LEGEND RF2300C/RFS2300 HEAD SECTION 1 Gear Motor 6 Water inlet valve 10 Low water level safety 11 Bin thermostat 17 Water level switch 18 Ice chute safety switch 21 Compressor Relay 24 On/Off switch 30 Rotation sensor 35 Compressor time delay by-pass 38 Solenoid Valve Wire Color Designation B White BL Blue G Grey M Brown N Black R Red A Orange Part Number 000007661 6/12 159
Condensing Units RCU CONDENSING UNIT 1PH 160 Part Number 000007661 6/12
RCU CONDENSING UNIT 3PH Part Number 000007661 6/12 161
Rack Models RF1279R/RFS1279R HEAD SECTION Power Supply To Remote Electrical Panel (Remove Bypass) To Refrigerating Plant 162 Part Number 000007661 6/12
WIRING DIAGRAM LEGEND RF1279R 1 Gear Motor 6 Water inlet valve 10 Low water level safety 11 Bin thermostat 17 Water level switch 18 Ice chute safety switch 21 Compressor Relay 24 On/Off switch 30 Rotation sensor 35 Compressor time delay by-pass 45 Suction Line Solenoid Valve 46 Liquid Line Solenoid Valve Wire Color Designation B White BL Blue G Grey M Brown N Black R Red V Violet A Orange Part Number 000007661 6/12 163
RF2379R/RFS2379R HEAD SECTION Power Supply To Remote Electrical Panel (Remove Bypass) To Refrigerating Plant 164 Part Number 000007661 6/12
WIRING DIAGRAM LEGEND RF2379R 1 Gear Motor 6 Water inlet valve 10 Low water level safety 11 Bin thermostat 17 Water level switch 18 Ice chute safety switch 21 Compressor Relay 24 On/Off switch 30 Rotation sensor 35 Compressor time delay by-pass 45 Suction Line Solenoid Valve 46 Liquid Line Solenoid Valve Wire Color Designation B White BL Blue G Grey M Brown N Black R Red V Violet A Orange Part Number 000007661 6/12 165
W B G WHITE INPUT POWER 4 3 2 BLACK 1 L M S YELLOW BLACK BLACK BLACK BLACK RUN START GEARM OTOR HIGH PRESSURE SAFETY SW ITCH ORANGE BLACK BLACK RED WHITE T.O.L. CONTROL BOARD COMPRESSOR FAN DRIVE L2 L2 L2 L2 L1 L1 L2 GRD BLACK WHITE S R M FAN WHITE WATER SENSOR 24V COMMON LINE VAC RED T.O.L.
Part Number 000007661 6/12 WHITE 4 YELLOW BLACK T.O.L. BLACK RED GEARMOTOR RUN START COMPRESSOR C 2 RED DRV COMP FAN L2 L1 BLACK 3 2 R S T.O.L. 1 5 WATER SENSOR BLACK BLACK HIGH PRESSURE SAFETY SWITCH COMPRESSOR SWITCH DR C 20M 60M 2ND WTR B-T B-E POWER RED RED VIOLET VIOLET WHITE BLACK WHITE BLACK ORANGE ORANGE BLACK POTENTIAL START RELAY GREEN/YELLOW BROWN BLUE WHITE BLACK WHITE RUN CAP.
RN1000/RN1400 AIR & WATER COOLED NORM LOW LE 2 COM LE 3 LE 4 LE 6 COM LE 7 DRAIN CLOG LE 8 1 2 3 4 NORM HIGH RETURN INPUT 2 (CONTACT CLOSURE) J51 RED / GRAY PAIR GRAY / GRAY PAIR JUMPER BIN FULL ALARM LOW WATER LEVEL MAINT MOM BLU -V BLK OR OUT (light on) BRN +V (3 WIRE) S3 CLEAN S2 PURGE 1 1 1 1 RESET SWITCH CONTROL PC BOARD J31 J32 J33 J34 H2O IN D15 J16 J15 J14 J13 FAN J2 COMP SOL C NO K3 AMP SENSINGL1 D6 K1 D9 TP3 TP6 DRV TP5 TP11 J7 J6 J5 J4 L2 J12 D10 TP4 J
RN1000C/RN1200C QUIETQUBE HEAD SECTION 4 6 LE 7 LE 8 LE 1 2 3 4 DRAIN CLOG BIN FULL COM LE NORM HIGH 3 ALARM LOW LE COM 2 RETURN (CONTACT CLOSURE) INPUT 2 LE NORM LOW OR WATER LEVEL BLU -V BRN +V J51 1 1 D10 H2O H2O DRN IN D15 AMP SENSING C K3 TP4 N TP11 L1 NO J12 J10 J11 J9 J8 J5 J6 J7 J4 FAN DRV J2 COMP SOL TP6 TP5 TP3 1 2 #34 #31 #32 #33 #30 JUMPER #21 #20 FCV-1 4 2 5 S1 1 20Watt 120Vac DRAIN 20Watt 120Vac FCV-2 P52 J52 WATER I
Refrigeration Tubing Schematics Flake Models RF0244/RFS0244/RF0266/RF0300/RF0385/RF0388/ RF0399/RF0644/RF0650 6 7 5 2 4 1 3 170 Part Number 000007661 6/12
TUBING DIAGRAM LEGEND 1 Compressor 2 Condenser 3 Liquid Line Drier 4 Capillary tube 5 Accumulator 6 Heat Exchanger 7 Evaporator Part Number 000007661 6/12 171
RF1200/RFS1200 AIR-COOLED 1 2 5 3 4 6 7 8 172 Part Number 000007661 6/12
TUBING DIAGRAM LEGEND 1 Compressor 2 Condenser 3 Liquid Line Drier 4 Liquid Line Solenoid Valve 5 Suction Accumulator 6 Thermostatic Expansion Valve 7 Liquid Accumulator 8 Evaporator Part Number 000007661 6/12 173
RF1200/RFS1200 WATER-COOLED 2 1 3 5 4 6 7 8 174 Part Number 000007661 6/12
TUBING DIAGRAM LEGEND 1 Compressor 2 Condenser 3 Liquid Line Drier 4 Liquid Line Solenoid Valve 5 Suction Accumulator 6 Thermostatic Expansion Valve 7 Liquid Accumulator 8 Evaporator Part Number 000007661 6/12 175
RF2300/RFS2300 AIR-COOLED 1 2 5 3 4 6 7 8 176 8 Part Number 000007661 6/12
TUBING DIAGRAM LEGEND 1 Compressor 2 Condenser 3 Liquid Line Drier 4 Liquid Line Solenoid Valve 5 Suction Accumulator 6 Thermostatic Expansion Valve 7 Liquid Accumulator 8 Evaporator Part Number 000007661 6/12 177
RF2300/RFS2300 WATER-COOLED 2 1 3 5 4 6 7 8 178 8 Part Number 000007661 6/12
TUBING DIAGRAM LEGEND 1 Compressor 2 Condenser 3 Liquid Line Drier 4 Liquid Line Solenoid Valve 5 Suction Accumulator 6 Thermostatic Expansion Valve 7 Liquid Accumulator 8 Evaporator Part Number 000007661 6/12 179
RF1200C/RFS1200C QUIETQUBE HEAD SECTION & RCU1075 CONDENSING UNIT 4 5 6 3 13 7 12 1 2 14 9 10 11 180 Part Number 000007661 6/12
TUBING DIAGRAM LEGEND 1 Compressor 2 Check Valve 3 Head Pressure Control Valve 4 Condenser (air or water cooled) 5 Receiver 6 Condensing unit Liquid Line Drier 7 Liquid Line Shut-off Valve 8 Ice Machine Liquid Line Drier 9 Liquid Line Solenoid Valve 10 Thermostatic Expansion Valve 11 Evaporator 12 Suction Line Shut-off Valve 13 Suction Line Filter 14 Suction Accumulator Part Number 000007661 6/12 181
RF2300C/RFS2300 QUIETQUBE HEAD SECTION & RCU2375 CONDENSING UNIT 4 5 6 3 14 7 1 13 2 15 9 10 12 11 182 11 Part Number 000007661 6/12
TUBING DIAGRAM LEGEND 1 Compressor 2 Check Valve 3 Head Pressure Control Valve 4 Condenser (air or water cooled) 5 Receiver 6 Condensing unit Liquid Line Drier 7 Liquid Line Shut-off Valve 8 Ice Machine Liquid Line Drier 9 Liquid Line Solenoid Valve 10 Thermostatic Expansion Valve 11 Evaporator 12 Liquid Accumulator 13 Suction Line Shut-off Valve 14 Suction Line Filter 15 Suction Accumulator Part Number 000007661 6/12 183
Nugget Models RNS0244/RNS0385/RN0400/RN1000/RN1400 AIR & WATER-COOLED 2 3 1 4 5 6 184 Part Number 000007661 6/12
TUBING DIAGRAM LEGEND 1 Compressor 2 Condenser (air or water cooled) 3 Liquid Line Drier 4 Heat Exchanger 5 Thermostatic Expansion Valve 6 Evaporator Part Number 000007661 6/12 185
RN1000C/RN1200C QUIETQUBE HEAD SECTION & RCU1075/RCU1275 CONDENSING UNIT 4 5 6 3 14 7 13 1 2 15 12 8 9 10 11 186 Part Number 000007661 6/12
TUBING DIAGRAM LEGEND 1 Compressor 2 Check Valve 3 Head Pressure Control Valve 4 Condenser (air or water cooled) 5 Receiver 6 Condensing unit Liquid Line Drier 7 Liquid Line Shut-off Valve 8 Ice Machine Liquid Line Drier 9 Liquid Line Solenoid Valve 10 Thermostatic Expansion Valve 11 Evaporator 12 S Trap (20’ + Rise Only) 13 Suction Line Shut-off Valve 14 Suction Line Filter 15 Suction Accumulator Part Number 000007661 6/12 187
This Page Intentionally Left Blank 188 Part Number 000007661 6/12
This Page Intentionally Left Blank Part Number 000007661 6/12 189
This Page Intentionally Left Blank 190 Part Number 000007661 6/12
Manitowoc Ice 2110 South 26th Street, P.O. Box 1720 Manitowoc, WI 54221-1720, USA Ph: 920-682-0161 Fax: 920-683-7589 Visit us online at: www.manitowocfsg.