Specifications
Part Number 000007661 7/10 9
Installation
Location of Ice Machine
The location selected for the ice machine must meet
the following criteria. If any of these criteria are not
met, select another location.
• The location must be free of airborne and other
contaminants.
• The location must not be near heat-generating
equipment or in direct sunlight.
• The location must be capable of supporting the
weight of the ice machine and a full bin of ice.
• The location must allow enough clearance for
water, drain and electrical connections in the rear
of the ice machine.
• The location must not obstruct airflow through or
around the ice machine.
Installation Requirements
• The air temperature must be at least 50°F (10°C),
but must not exceed 110°F (43°C).
• The water temperature must be at least 40°F
(4°C), but must not exceed 90°F (32°C).
• The ice machine and bin must be level.
• Vent the ice machine and bin drains separately.
• Bin drain termination must have an air gap.
• RF Models Only: A backflow preventer is required
on water inlet lines.
• Routine adjustments and maintenance procedures
outlined in this manual are not covered by the
warranty.