Specifications

Part Number 000007661 7/10 9
Installation
Location of Ice Machine
The location selected for the ice machine must meet
the following criteria. If any of these criteria are not
met, select another location.
The location must be free of airborne and other
contaminants.
The location must not be near heat-generating
equipment or in direct sunlight.
The location must be capable of supporting the
weight of the ice machine and a full bin of ice.
The location must allow enough clearance for
water, drain and electrical connections in the rear
of the ice machine.
The location must not obstruct airflow through or
around the ice machine.
Installation Requirements
The air temperature must be at least 50°F (10°C),
but must not exceed 110°F (43°C).
The water temperature must be at least 40°F
(4°C), but must not exceed 90°F (32°C).
The ice machine and bin must be level.
Vent the ice machine and bin drains separately.
Bin drain termination must have an air gap.
RF Models Only: A backflow preventer is required
on water inlet lines.
Routine adjustments and maintenance procedures
outlined in this manual are not covered by the
warranty.