Specifications
72 Part Number 000007661 7/10
YES
HI AMPS Light Off?
YES
Reset Breaker - Press Control Board 
Reset Button To Clear Error
Circuit Breaker On 
Control Box Tripped?
YES
NO
Line Voltage To 
Gear Motor?
NO
NO
Press Control 
Board Reset Button To 
Clear Error
Replace Control 
Board
NO
Gear Motor Runs?
YES
Clean Ice Machine - Install Water Filter - Increase 
Cleaning Frequency -Verify Shuttle Shuts Off Ice 
Machine – Test Run 
Check Wires & Connections 
Replace Gear Motor
NO
YES