Specifications
Part Number 000005653 10/09 7
Section 3
Operation
NOTE: Flake ice machines use an auger to remove ice
from the evaporator. Occasional noises (creaks, groans,
squeaks, or pops) are a normal part of the ice making
process.
Evaporator Low Temperature Safety
Thermostat and Bin Thermostat
The bin thermostat sensing bulb is located in the ice
chute or bin and turns the ice machine on and off as the
level of ice in the ice chute or bin changes.
RF-0244/RF0266/RF-0388/RF0399 Operation
The ice machine will not start until:
A. The rocker switch is moved to “ON”.
B. Ice does not contact the bin thermostat bulb.
C. The water reservoir is full of water.
Placing the toggle switch in the ON position starts the
gear motor and refrigeration system. The float valve
controls the water inlet valve and water level. The freeze
cycle ends when ice contacts the bin thermostat. The ice
machine will restart when ice no longer contacts the bin
thermostat.
RF-0300 Operation
The ice machine will not start until:
A. The rocker switch is moved to “ON”.
B. Ice does not contact the bin thermostat bulb.
C. The water reservoir is full of water.
Placing the toggle switch in the ON position starts the
gear motor and a 10 minute compressor time delay. The
compressor starts and the float valve controls the water
inlet valve and water level. The freeze cycle ends when
ice contacts the bin thermostat. The ice machine remains
off until ice no longer contacts the bin thermostat.
RF-650/RF-1200/RF-2300 Operation
The ice machine will not start until:
A. The rocker switch is moved to “ON”.
B. Ice does not contact the bin thermostat bulb.
C. The water reservoir is full of water.
Placing the toggle switch in the ON position starts the
gear motor. After the rotation speed sensor verifies
10 minutes of correct rotation, the time delay ends and
the compressor starts. The ice machine will continue to
make ice until ice contacts the bin thermostat. The ice
machine remains off until ice no longer contacts the bin
thermostat.
Model
Bin
Thermostat
Setting
Evaporator
Thermostat
Setting
RF-0244/RF0266/RF 5 5
RF-0388/RF-399 5 7
RF0300 4 7
RF0650 4 N/A
RF1200/RF-2300 5 N/A
1
2
3
4
5
6
7
1
2
3
4
5
6
7
BIN THERMOSTAT
SMALL NUMBERS = LESS ICE IN BIN
LARGE NUMBERS = MORE ICE IN BIN
EVAPORATOR LOW TEMPERATURE
SAFETY THERMOSTAT
INCORRECT SETTINGS WILL CAUSE ICE
MACHINE TO SHUT OFF
SENSING BULB IS
LOCATED IN BIN
BIN THERMOSTAT
LOCATION
EVAPORATOR LOW
TEMPERATURE SAFETY
THERMOSTAT LOCATION
BIN THERMOSTAT
EVAPORATOR
THERMOSTAT
BIN THERMOSTAT IS
LOCATED ON SIDE OF
CONTROL BOX