Specifications
4 Part Number 000005653 10/09
Section 2
Installation Instructions
Location of Ice Machine
The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met,
select another location.
• The location must be free of airborne and other
contaminants.
• The air temperature must be at least 50°F (10°C), but
must not exceed 110°F (43°C).
• The water temperature must be at least 40°F (4°C),
but must not exceed 90°F (32°C).
• The location must not be near heat-generating
equipment or in direct sunlight.
• The location must be capable of supporting the
weight of the ice machine and a full bin of ice.
• The location must allow enough clearance for water,
drain and electrical connections in the rear of the ice
machine.
• The location must not obstruct airflow through or
around the ice machine.
CLEARANCE REQUIREMENTS
Installation Requirements
• The ice machine and bin must be level.
• Vent the ice machine and bin drains separately.
• Bin drain termination must have an air gap.
• A backflow preventer is required on water inlet lines.
• The ice machine and bin must be sanitized after
installation.
• Local water conditions may require treatment of the
water to inhibit scale formation, filter sediment, and
remove chlorine odor and taste.
• Routine adjustments and maintenance procedures
outlined in this manual are not covered by the
warranty.
RF-2300 Bin Adapter Installation
1. Refer to diagram. Place bracket on bin top and slide
back to engage.
2. Place ice machine on bin: ice machine must fit
between bracket and front ridge.
RF-0244
RF-0266
RF-0388
RF-0399
Air-Cooled Water-Cooled
Top/Sides 8" (20 cm) 8" (20 cm)
Back 5" (13 cm) 5" (13 cm)
NOTE: Allowance must be made for removal when the
ice machine is built in. Monthly removal of the top
panel is required for cleaning & sanitizing.
RF-0300
RF-0650
RF-1200
RF-2300
Air-Cooled Water-Cooled
Top/Sides 8" (20 cm) 8" (20 cm)
Back 5" (13 cm) 5" (13 cm)
!
Warning
PERSONAL INJURY POTENTIAL
RF-2300 ice machines are not approved for use on
B970 bins. RF-2300 ice machines ship with a
bracket that must be used when installing on B1100
and B1400 Series bins.