Specifications
Section 4 Maintenance
Part Number 000005653 10/09 11
ICE CHUTE SWITCH ACTUATOR REMOVAL
RF-0300/RF-0650/RF-1200/RF-2300 Only
1. Pull to remove nylon end cap.
2. Slide pin to remove.
3. Remove both sections of the pressure switch
bracket.
Air-Cooled Condenser Cleaning
A dirty condenser restricts airflow, resulting in
excessively high operating temperatures and reduced
ice production. Clean the condenser at least every six
months.
1. Clean the outside of the condenser with a soft brush
or a vacuum with a brush attachment. Shine a
flashlight through the condenser to check for dirt
between the fins. If dirt remains, a method suitable
to remove the contamination must be used to ensure
air flow.
2. RF-0300/RF-0650/RF-1200/RF-2300 Only. Clean
the washable filter with a mild soap and water
solution.
Arctic Pure Water Filter System
Engineered specifically for Manitowoc ice machines.
This water filter is an efficient, dependable, and
affordable method of inhibiting scale formation, filtering
sediment, and removing chlorine taste and odor.
Manitowoc Cleaner and Sanitizer
Manitowoc Ice Machine Nickel Safe Cleaner is available
in convenient 16 oz. (473 ml) bottles. Manitowoc Ice
Machine Sanitizer is available in 16 oz. (473 ml) and
1 gal (3.78 L) bottles.
INCORRECT REASSEMBLY
CAN RESULT IN AN ICE
MACHINE THAT WILL NOT RUN
!
Warning
Disconnect electric power to the ice machine and
the remote condenser at the electric service switch
before cleaning the condenser.
!
Caution
The condenser fins are sharp. Use care when
cleaning them.
Cleaner Part Number Sanitizer Part Number
16 oz. 000000084 16 oz. 94-0565-3
1 Gallon 94-0581-3