Specifications
Maintenance Section 4
10
Part Number 000005653 10/09
Removal of Parts for Cleaning/Sanitizing
1. Turn off the water supply to the ice machine at the
water service valve.
2. Remove the components listed on the following
pages for cleaning and sanitizing.
3. Soak the removed part(s) in a properly mixed
solution of cleaner and water.
4. Use a soft-bristle brush or sponge (NOT a wire
brush) to carefully clean the parts.
5. Use the solution and a brush or sponge to clean all
disassembled components and the inside of the bin.
6. Rinse all cleaned parts with clear water.
7. Mix a solution of sanitizer and water.
8. Soak the parts in the sanitizer/water solution for
10 minutes. Use the sanitizer/water solution and a
sponge to sanitize all removed components and the
inside of the bin. Do not rinse the sanitized parts.
9. Continue with step 11 of the cleaning/sanitizing
procedure.
ICE CHUTE REMOVAL
RF-0300/RF-0650/RF-1200/RF-2300 O
NLY
1. Place the toggle switch in the OFF position, turn off
the water supply and disconnect electrical power to
the ice machine.
2. Disconnect water supply.
3. Remove water reservoir cover.
4. Remove bin thermostat from ice chute.
5. Loosen bolts holding cross member.
6. Lift cross member and remove ice chute.
!
Warning
Disconnect electric power to the ice machine at the
electric switch box and wear rubber gloves and
safety goggles (or face shield) while handling cleaner
or sanitizer.
!
Caution
Do not mix Cleaner and Sanitizer solutions together.
It is a violation of Federal law to use these solutions
in a manner inconsistent with their labeling.
Solution Type Water Mixed With
Cleaner 1 gal. (4 L) 16 oz (500 ml) cleaner
Part Number 000000084
Solution Type Water Mixed With
Sanitizer 3 gal. (11 L) 2 oz (60 ml) sanitizer
Part Number 94-0565-3
LOOSEN
SUPPORT BOLTS
TIP TOP OF ICE
CHUTE BACK AND
LIFT TO REMOVE