Service Manual
Section 7 Refrigeration System
Part No. 80-1100-3 7-27
HARVEST PRESSURE REGULATING
(H.P.R.) SYSTEM
Remotes Only
GENERAL
The harvest pressure regulating (H.P.R.) system 
includes:
• Harvest pressure regulating solenoid valve (H.P.R. 
solenoid). This is an electrically operated valve which 
opens when energized, and closes when de-
energized.
Figure 7-12. H.P.R. Solenoid
• Harvest pressure regulating valve (H.P.R. valve). 
This is a non-adjustable pressure regulating valve 
which modulates open and closed, based on the 
refrigerant pressure at the outlet of the valve. The 
valve closes completely and stops refrigerant flow 
when the pressure at the outlet rises above the valve 
setting.
Figure 7-13. H.P.R. Valve
SV1427
INLET OUTLET
FLOW
SV3053
OUTLET
INLET