Service Manual
Refrigeration System Section 7
7-10 Part No. 80-1100-3
INSTALLATION/VISUAL INSPECTION CHECKLIST WATER SYSTEM CHECKLIST
A water-related problem often causes the same 
symptoms as a refrigeration system component 
malfunction.
Example: A water dump valve leaking during the freeze 
cycle, a system low on charge, and a starving TXV have 
similar symptoms.
Water system problems must be identified and 
eliminated prior to replacing refrigeration components.
Possible Problem Corrective Action
Ice machine is not level Level the ice machine
Improper clearance around 
top, sides and/or back of ice 
machine
Reinstall according to the 
Installation Manual
Air-cooled condenser filter is 
dirty
Clean the condenser filter 
and/or condenser
Ice machine is not on an 
independent electrical circuit
Reinstall according to the 
Installation Manual
Water filtration is plugged (if 
used)
Install a new water filter
Water drains are not run 
separately and/or are not 
vented
Run and vent drains 
according to the Installation 
Manual
Remote condenser line set is 
improperly installed
Reinstall according to the 
Installation Manual
Possible Problem Corrective Action
Water area (evaporator) is 
dirty
Clean as needed
Water inlet pressure not 
between 20 and 80 psi
Install a water regulator valve 
or increase the water 
pressure
Incoming water temperature 
is not between 35°F (1.7°C) 
and 90°F (32.2°C).
If too hot, check the hot water 
line check valves in other 
store equipment
Water filtration is plugged (if 
used)
Install a new water filter
Water dump valve leaking 
during the freeze cycle
Clean/replace dump valve as 
needed
Vent tube is not installed on 
water outlet drain
See Installation Instructions
Hoses, fittings, etc., are 
leaking water
Repair/replace as needed
Water fill valve is stuck open Clean/replace as needed
Water is spraying out of the 
sump trough area
Stop the water spray
Uneven water flow across the 
evaporator
Clean the ice machine
Water is freezing behind the 
evaporator
Correct the water flow
Plastic extrusions and 
gaskets are not secured to 
the evaporator
Remount/replace as needed
Water does not flow over the 
evaporator (not trickle) 
immediately after the prechill
Clean/replace water level 
probe as needed