Specifications

Part Number 80-1230-9 6/08 99
Procedure to Clean Heavily Scaled Ice Machines
QC0700/QF0800/QF2200/QF2300
Step 1 Remove all ice from the bin.
Step 2 Remove front and top covers and set the
toggle switch to the OFF position.
Step 3 Disconnect water supply line at float valve
quick disconnect by depressing stainless steel lever.
Step 4 Refer to chart below:
Premix cleaner with lukewarm water in a
non-metallic container.
!
Caution
Use Manitowoc clear (P/N 000000084) Ice
Machine Cleaner only. It is a violation of Federal
law to use these solutions in a manner
inconsistent with their labeling. Read and
understand all labels printed on bottles before
use.
Model
Water
Reservoir
Capacity
Mix Cleaner (Part #000000084)
and Water
Cleaner Water
QF0800/
QC0700
48 oz (1.4 L) 32 oz (0.94 L) 16 oz (0.5 L)
QF2200/
QF2300
72 oz (2.1 L) 48 oz (1.4 L) 24 oz (0.7 L)