Specifications

98 Part Number 80-1230-9 6/08
Step 5 Wait 45 seconds until the Dump Valve light
de-energizes and the Water Level Probe light
energizes. Fill the water reservoir with the pre-mixed
solution of sanitizer/water. When water contacts the
water level probe, the compressor will energize.
The ice machine will freeze and discharge the
sanitizing solution into the bin. Add the remaining
sanitizer/water solution when the water level in the
reservoir drops.
NOTE: Do not allow the water level to drop below the
water level probes. The ice machine will discontinue
the cycle when the water level probes open (lose
water contact) for more than 90 seconds (30 seconds
on replacement boards).
Step 6 After the entire sanitizer/water solution has
been added to the reservoir, reconnect the water
supply line at the float valve quick disconnect.
The ice machine will continue to freeze and discharge
the sanitizing solution into the bin.
Allow the cycle to run for ten minutes to remove all
sanitizing solution from the water reservoir.
Step 7 Place the toggle switch in the OFF position
and refer to disassembly for cleaning and sanitizing.
NOTE: Discard all ice produced during the sanitizing
process.