Specifications

96 Part Number 80-1230-9 6/08
Step 7 Wait 45 seconds until the Dump Valve light
de-energizes and the Water Level Probe light
energizes. Add the proper amount of Manitowoc Ice
Machine Cleaner to the water reservoir..
Step 8 Reconnect the water supply line to the float
valve. When water contacts the water level probe, the
compressor will energize. The ice machine will freeze
and discharge the cleaning solution into the bin.
Continue the Freeze cycle for ten minutes to remove
all cleaning solution from the water reservoir.
Step 9 Place the toggle switch in the OFF position
and refer to sanitizing procedure. Discard all ice
produced during the cleaning process.
!
Caution
Use Manitowoc clear (P/N 000000084) Ice
Machine Cleaner only. It is a violation of Federal
law to use these solutions in a manner
inconsistent with their labeling. Read and
understand all labels printed on bottles before
use.
Model
Amount of Cleaner
(Part #000000084)
QF0800/QC0700 3 oz. (90 ml)
QF2200/QF2300 3 oz. (90 ml)