Cleaning Procedure
QC0700/QF0800/QF2200/QF2300
Ice machine cleaner is used to remove lime scale or
other mineral deposits. It is not used to remove algae
or slime. Refer to “Sanitizing Procedure” for removal of
algae and slime.
Step 1 Remove front and top cover and set the
toggle switch to the OFF position.
Step 2 Remove all ice from the bin/dispenser.
Step 3 Disconnect water supply line at float valve
quick disconnect by depressing stainless steel lever.
Step 4 Remove the top cover from the water
reservoir.
Step 5 Remove the water level probes from the top
cover and with wires attached, place the water level
probes (stand upright) inside the water reservoir.
Step 6 To start the cleaning procedure, move the
toggle switch to the ICE position. The gear motor will
start and the water dump valve will energize. Water
will flow through the water dump valve and down the
drain. The control board light for the dump valve, gear
motor, and speed will energize to indicate the ice
machine is starting the ice making sequence.