Specifications

82 Part Number 80-1230-9 6/08
Sanitizing Procedure
QF400
Ice machine sanitizer is used to remove algae or
slime. It is not used to remove lime scale or other
mineral deposits. Refer to “Cleaning Procedure” for
removal of remove lime scale or other mineral
deposits.
Step 1 Perform cleaning procedure before sanitizing
the ice machine.
Step 2 Disconnect water supply line at float valve
quick disconnect by depressing stainless steel lever.
Step 3 Mix 2 oz. (60 ml) of Manitowoc Ice Machine
Sanitizer with 3 gal. (11 L) of cool water.
Step 4 To start the sanitizing procedure, move the
toggle switch to the ICE position. The gear motor will
start and the water dump valve will energize. Water
will flow through the water dump valve and down the
drain. The control board light for the dump valve, gear
motor, and speed will energize to indicate the ice
machine is starting the ice making sequence.
Model
Amount of
Sanitizer/Water
QF0400
2 oz. (60 ml)
mixed with 3 gal.
(11 L) cool water