Specifications

Part Number 80-1230-9 6/08 59
13. Mix a solution of cleaner and warm water.
Depending upon the amount of mineral buildup, a
larger quantity of solution may be required. Use
the ratio in the table below to mix enough solution
to thoroughly clean all parts.
14. The cleaner solution will foam when it contacts
lime scale and mineral deposits; once the foaming
stops use a soft-bristle nylon brush, sponge or
cloth (NOT a wire brush) to carefully clean the
parts. Soak parts for 5 minutes (15 - 20 minutes
for heavily scaled parts). Rinse all components
with clean water.
15. While components are soaking clean all foodzone
surfaces of the bin (or dispenser). Rinse all areas
thoroughly with clean water.
16. .Mix a solution of sanitizer and warm water.
!
Caution
Do not mix Cleaner and Sanitizer solutions
together. It is a violation of Federal law to use
these solutions in a manner inconsistent with
their labeling.
Solution Type Water Mixed With
Cleaner 1 gal. (4 l)
16 oz (500 ml)
cleaner
Solution Type Water Mixed With
Sanitizer 6 gal. (23 l)
4 oz (120 ml)
sanitizer