Specifications
Part Number 80-1230-9 6/08 247
Component Specifications
MAIN FUSE
The main fuse is 250 Volt, 10 amp.
BIN SWITCH
The bin switch is a magnetically operated reed switch.
The magnet is attached to the lower right corner of the
water curtain. The switch is attached to the right
bulkhead wall.
The bin switch is connected to a varying D.C. voltage
circuit. (Voltage does not remain constant.)
NOTE: Because of a wide variation in D.C. voltage, it
is not recommended that a voltmeter be used to check
bin switch operation.
ICE/OFF/CLEAN TOGGLE SWITCH
Single-pole, double-throw switch. The switch is
connected into a varying low D.C. voltage circuit.
FAN CYCLE CONTROL
(Self-Contained Air-Cooled Models Only)
HIGH PRESSURE CUTOUT (HPCO) CONTROL
TORQUE VALUES
Model Cut-In (Close) Cut-Out (Open)
QF800/QC700
250 ±5
(1723 kPa ±.34)
(17.23 bar ±.34)
200 ±5
(1517 kPa ±.34)
(15.17 bar ±.34)
Cut-Out Cut-In
450 psig ±10
(3103 kPa ±69)
31 bar ±.69
Automatic Reset
(Must be below 300 psig
(2068 kPa 20.68 bar) to reset.)
Location Inch Pounds Set Screws
M24 Coupling 5-20 #10-24
Evap to Foundation 60 +/- 5 #1/4-20
Use Loctite 242