Specifications

Part Number 80-1230-9 6/08 149
RESET PROCEDURE
1. Move the ICE/OFF/CLEAN toggle switch to OFF.
A. If a safeguard feature has stopped the ice
machine, it will restart after a short delay.
Proceed to Step 2.
B. If the ice machine does not restart, see “Ice
Machine Does Not Operate.”
2. Allow the ice machine to run to determine if the
condition is reoccurring.
A. If the ice machine continues to run, the
condition has corrected itself. Allow the ice
machine to continue running.
B. If the ice machine stops determine the
safeguard mode, then refer to the specific
safeguard for troubleshooting procedures.
ANALYZING WHY SAFEGUARDS MAY STOP
THE ICE MACHINE
According to the refrigeration industry, a high
percentage of compressor failure is a result of external
causes. These can include flooding or starving
expansion valves, dirty condensers, water loss to the
ice machine, etc. SafeGuards protect the ice machine
(primarily the compressor) from external failures by
stopping ice machine operation before major
component damage occurs.
Refrigeration and electrical component failures may
also trip a safeguard. Eliminate all electrical
components and external causes first. If it appears
that the refrigeration system is causing the problem,
use the charts, checklists, and other references to
determine the cause.
NOTE: The following checklists are designed to assist
the service technician in analysis. However, because
there are many possible external problems, do not
limit your diagnosis to only the items listed.