Water Level Probe Removal
1. Place the toggle switch in the OFF position, turn off the
water supply and disconnect electrical power to the ice
machine.
2. Disconnect water supply line at float valve quick disconnect
by depressing stainless steel lever.
3. Pull up on water level probes to remove.
4. Clean in place or disconnect wires from water level probes.
Water Level Probe Removal
Float Valve Removal
1. Place the toggle switch in the OFF position, turn off
the water supply and disconnect electrical power to
the ice machine.
2. Disconnect water supply line at float valve quick
disconnect by depressing stainless steel lever.
3. Remove water float valve coil.
4. Depress coil and rotate 1/4 turn counterclockwise.
5. With coil wires attached, lift coil off enclosure tube.
6. Remove top cover from float reservoir.
7. Lift float valve out of float reservoir.
Float Valve Removal
WATER LEVEL
PROBES
SV2043
DEPRESS TAB TO
REMOVE WATER
INLET LINE
DEPRESS AND TWIST
COIL 1/4 TURN, THEN
LIFT TO REMOVE
PULL UP ON WATER LEVEL PROBES TO REMOVE -
CLEAN IN PLACE OR DISCONNECT WIRES