Specifications
Installation Instructions Section 2
2-10 Part Number 000001759
GENERAL
Condensers must be mounted horizontally with the fan 
motor on top.
Remote condenser installations consist of vertical and 
horizontal line sets between the ice machine and the 
condenser. When combined, they must fit within 
approved specifications. The following guidelines, 
drawings and calculation methods must be followed to 
verify a proper remote condenser installation.
GUIDELINES FOR ROUTING LINE SETS
First, cut a 64 mm circular hole in the wall or roof for 
tubing routing. The line set end with the 90° bend will 
connect to the ice machine. The straight end will connect 
to the remote condenser.
Follow these guidelines when routing the refrigerant 
lines. This will help insure proper performance and 
service accessibility.
1. Optional - Make the service loop in the line sets (See 
below). This permits easy access to the ice machine 
for cleaning and service. Do not use hard rigid 
copper at this location.
2. Required - Do not form traps in the refrigeration lines 
(except the service loop). Refrigerant oil must be 
free to drain toward the ice machine or the 
condenser. Route excess tubing in a supported 
downward horizontal spiral (See below). Do not coil 
tubing vertically.
3. Required - Keep outdoor refrigerant line runs as 
short as possible.
Routing Line Sets
!
Caution
The 60 month compressor warranty (including the 
36 month labor replacement warranty) will not apply 
if the remote ice machine is not installed according 
to specifications.
This warranty also will not apply if the refrigeration 
system is modified with a condenser, heat reclaim 
device, or other parts or assemblies not 
manufactured by Manitowoc Ice, Inc., unless 
specifically approved in writing by Manitowoc Ice, 
Inc.
1
2
3
1
2
3
DOWNWARD
HORIZONTAL
SPIRAL
SV1204