Specifications

22 Part Number STH044 10/13
SEQUENCE OF OPERATION CHART
Nugget Machines
Sequence
Contactor
Coil
Dump
Valve
Gear
Motor
Ice Damper Duration
Initial Start-Up
The 15 minute delay must expire
first
Off Off On Closed Immediate
Freeze Cycle On Off On
Moves to Verify
Ice Production
Until Ice Holds Damper
Open
Automatic Shut-Off Off Off Off Open Until Damper Closes
Restart
More than 30 minutes have
passed since automatic shutoff
cycle initiated
Off On On Closed 30 Seconds
Restart
Less than 30 minutes have
passed since automatic shutoff
cycle initiated
Off Off On Closed Immediate