Manitowoc Q130/Q170/Q210/Q270 UnderCounter Model Ice Machine Installation, Use & Care Manual This manual is updated as new information and models are released. Visit our website for the latest manual. www.manitowocice.
Table of Contents Section 1 General Information Model Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bin Caster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Arctic Pure Water Filter System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table of Contents (continued) Section 4 Maintenance Interior Cleaning and Sanitizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cleaning and Sanitizing Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ice Machine Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Section 1 General Information Safety Notices Read These Before Proceeding: As you work on Manitowoc equipment, be sure to pay close attention to the safety notices in this handbook. Disregarding the notices may lead to serious injury and/or damage to the equipment. Throughout this handbook, you will see the following types of safety notices: ! Caution Proper installation, care and maintenance are essential for maximum performance and trouble-free operation of your equipment. Visit our website www.
Section 1 General Information ! Warning Do not operate equipment that has been misused, abused, neglected, damaged, or altered/modified from that of original manufactured specifications. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision concerning use of the appliance by a person responsible for their safety.
General Information Section 1 Model Numbers Accessories This manual covers the following models: Contact your Manitowoc distributor for these optional accessories: Self-Contained Air-Cooled QR0130A QD0132A QY0134A QD0172A QY0174A QR0210A QD0212A QY0214A QYP0214A QR0270A QD0272A QY0274A QYP0274A Self-Contained Water-Cooled QR0131W QD0133W QY0135W --QR0211W QD0213W QY0215W -QR0271W QD0273W QY0275W -- ! Warning PERSONAL INJURY POTENTIAL This appliance is not intended for use by persons (including child
Section 2 Installation Instructions Location of Ice Machine Ice Machine Heat of Rejection The location selected for the ice machine must meet the following criteria. If any of these criteria are not met, select another location. • The location must be indoors. • The location must be free of airborne and other contaminants. • The air temperature must be at least 40°F (4°C), but must not exceed 110°F (43°C). • The location must not be near heat-generating equipment or in direct sunlight.
Installation Instructions Section 2 Electrical Service TOTAL CIRCUIT AMPACITY GENERAL The total circuit ampacity is used to help select the wire size of the electrical supply. ! Warning All wiring must conform to local, state and national codes. The wire size (or gauge) is also dependent upon location, materials used, length of run, etc., so it must be determined by a qualified electrician.
Section 2 Installation Instructions Water Service/Drains DRAIN CONNECTIONS WATER SUPPLY Follow these guidelines when installing drain lines to prevent drain water from flowing back into the ice machine and storage bin: Local water conditions may require treatment of the water to inhibit scale formation, filter sediment, remove chlorine, and improve taste and clarity. ! Warning PERSONAL INJURY POTENTIAL For ice making, connect to a potable water supply only.
Installation Instructions Section 2 Before Starting the Ice Machine All Manitowoc ice machines are factory-operated and adjusted before shipment. Normally, new installations do not require any adjustment. To ensure proper operation, follow the Operational Checks in Section 3 of this manual. Starting the ice machine and completing the Operational Checks are the responsibilities of the owner/operator. Adjustments and maintenance procedures outlined in this manual are not covered by the warranty.
Section 3 Operation Section 3 Operation Ice Making Sequence of Operation HARVEST SEQUENCE INITIAL START-UP OR START-UP AFTER AUTOMATIC SHUT-OFF 5. Harvest 1. Pressure Equalization Before the compressor starts the hot gas valve is energized for 15 seconds to equalize pressures during the initial refrigeration system start-up. 2. Refrigeration System Start-Up The compressor starts after the 15-second pressure equalization, and remains on throughout the entire Freeze and Harvest Sequences.
Operation Section 3 Energized Parts Chart CONTROL BOARD RELAYS INITIAL START-UP/ START UP AFTER AUTO SHUT-OFF: 1. Pressure Equalization 2. Refrigeration System Start-up FREEZE SEQUENCE: RELAY 1 2 3 3A 3B WATER PUMP HOT GAS VALVE RELAY COIL COMPRESSOR CONDENSER ∗ FAN MOTOR OFF ON OFF OFF OFF 15 Seconds OFF ON ON ON ON 5 Seconds OFF OFF ON ON ON 30 Seconds 3. Pre-Chill 4. Freeze ON OFF ON ON ON Until 7 sec.
Section 3 Operation Operational Checks WATER FLOAT VALVE CHECK GENERAL Before water will flow into the water trough the float valve shut-off must be in the OPEN position. Your Manitowoc ice machine was factory-operated and adjusted before shipment. Normally, a newly installed ice machine does not require any adjustment.
Operation Section 3 WATER LEVEL CHECK ICE BRIDGE THICKNESS CHECK Check the water level while the ice machine is in the ice mode and the water pump is running. The correct water level is 1/4" (6.3mm) to 3/8" (9.5mm) below the top of the standpipe a line in the water trough indicates the correct level. The ice thickness probe is factory-set to maintain the ice bridge thickness at 1/8" (3.2 mm). SIPHON CAP 1. Inspect the bridge connecting the cubes. It should be about 1/8" (3.2 mm) thick. 2.
Section 4 Maintenance Section 4 Maintenance Interior Cleaning and Sanitizing GENERAL Clean and sanitize the ice machine every six months for efficient operation. If the ice machine requires more frequent cleaning and sanitizing, consult a qualified service company to test the water quality and recommend appropriate water treatment. The ice machine must be taken apart for cleaning and sanitizing. Ice machine cleaner is used to remove lime scale and mineral deposits.
Maintenance Section 4 Step 6 Remove parts for cleaning. D. Remove the Ice Thickness Probe • Compress the side of the ice thickness probe near the top hinge pin and remove it from the bracket. A. Remove Two Thumbscrews and Water Pump Cover (When Used). B. Remove the Vinyl Hose Connecting the Water Pump and Water Distribution Tube ICE THICKNESS PROBE C.
Section 4 Maintenance E. Remove the Water Distribution Tube Q130 Models Q170/Q210/Q270 Models DISTRIBUTION TUBE 2 3 1. LIFT UP 2. SLIDE BACK 3. SLIDE TO RIGHT 1 DISTRIBUTION TUBE THUMBSCREW THUMBSCREW LOCATING PIN THUMBSCREW REMOVE ICE THICKNESS PROBE THUMBSCREW Q170/Q210/Q270 Water Distribution Tube Removal Q130 Water Distribution Tube Removal • Loosen the two thumbscrews, which secure the distribution tube. • Loosen the two thumbscrews, which secure the distribution tube.
Maintenance Section 4 F. Remove the Float Valve • G. Remove the Water Trough Turn the splash shield counterclockwise one or two turns. FLOAT VALVE BRACKET COMPRESSION FITTING • Apply downward pressure on the siphon tube and remove from the bottom of the water trough. • Remove the upper thumbscrew. • While supporting the water trough remove the two thumbscrews from beneath the water trough. • Remove the water trough from the bin area.
Section 4 Maintenance H. Remove the ice damper. Q130 • • Grasp left side of ice damper and apply pressure against the right-hand ice damper mounting bracket. I. Remove the Bin Door • Grasp the rear of the bin door and pull bin door forward approximately 5". • Slide bin door to the rear while applying upward pressure (The rear door pins will ride up into the track slot and slide backward to the stop tab).
Maintenance Section 4 Step 7 Mix a solution of cleaner and warm water. Depending on the amount of mineral buildup, a larger quantity of solution may be required. Use the ratio in the table below to mix enough solution to thoroughly clean all parts. Solution Type Water Mixed with Cleaner 1 gal. (4 l) 16 oz (500 ml) cleaner Step 8 Use ½ of the cleaner/water solution to clean all components.
Section 4 Maintenance Step 16 Wait until the sanitize cycle is complete (approximately 22 minutes) then place the toggle switch in the OFF position, disconnect power and water supplies to the ice machine. ! Warning Disconnect electric power to the ice machine at the electric switch box before proceeding. Step 17 Repeat step 6 to remove parts for hand sanitizing. Step 18 Mix a solution of sanitizer and warm water. Solution Type Sanitizer Water 6 gal.
Maintenance Section 4 Ice Machine Inspection Cleaning the Condenser Check all water fittings and lines for leaks. Also, make sure the refrigeration tubing is not rubbing or vibrating against other tubing, panels, etc. GENERAL ! Warning Disconnect electric power to the ice machine head section and the remote condensing unit at the electric service switches before cleaning the condenser. Do not put anything (boxes, etc.) in front of the ice machine.
Section 5 Customer Support Checklist If a problem arises during operation of your ice machine, follow the checklist below before calling service. Routine adjustments and maintenance procedures are not covered by the warranty. Problem Ice machine does not operate. Ice machine stops, and can be restarted by moving the toggle switch to OFF and back to ON. Ice machine does not release ice or is slow to harvest. Ice machine does not cycle into harvest mode. Ice quality is poor (soft or not clear).
Customer Support Problem Ice machine produces shallow or incomplete cubes, or the ice fill pattern on the evaporator is incomplete. Section 5 Possible Cause Ice thickness probe is out of adjustment. Water trough level is to high or too low. Water float valve filter screen is dirty. Water filtration is poor. Hot incoming water. Water float valve is not working. Incorrect incoming water pressure. Low ice capacity. Ice machine is not level. Water float valve filter screen is dirty.
Section 5 Customer Support Commercial Ice Machine Warranty Manitowoc Ice, Inc. (hereinafter referred to as the “COMPANY”) warrants for a period of thirty-six months from the installation date (except as limited below) that new ice machines manufactured by the COMPANY shall be free of defects in material or workmanship under normal and proper use and maintenance as specified by the COMPANY and upon proper installation and start-up in accordance with the instruction manual supplied with the ice machine.
Customer Support Section 5 Residential Ice Machine Limited Warranty WHAT DOES THIS LIMITED WARRANTY COVER? Subject to the exclusions and limitations below, Manitowoc Foodservice (“Manitowoc”) warrants to the original consumer that any new ice machine manufactured by Manitowoc (the “Product”) shall be free of defects in material or workmanship for the warranty period outlined below under normal use and maintenance, and upon proper installation and start-up in accordance with the instruction manual supplied
Table des matières Section 1 Généralités Références des modèles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessoires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Roulettes de bac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Système de filtration d’eau Arctic Pure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table of Contents (continued) Section 4 Entretien Nettoyage et désinfection intérieurs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Généralités . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Procédure de nettoyage et de désinfection . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inspection de la machine à glaçons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nettoyage extérieur . . . . . .
Section 1 Généralités Références des modèles Accessoires Le présent manuel s’applique aux modèles suivants : Contacter le distributeur Manitowoc pour obtenir ces accessoires en option : Autonomes refroidis à l’air QR0130A QD0132A QY0134A QD0172A QY0174A QR0210A QD0212A QY0214A QYP0214A QR0270A QD0272A QY0274A QYP0274A Autonomes refroidis à l’eau QR0131W QD0133W QY0135W --QR0211W QD0213W QY0215W -QR0271W QD0273W QY0275W -- ! Avertissement RISQUE DE BLESSURES CORPORELLES Le présent appareil ne doit pas
Section 2 Instructions d’installation Emplacement de la machine à glaçons Le choix de l’emplacement pour la machine à glaçons doit respecter les critères suivants. Si l’un de ces critères n’est pas respecté, choisir un autre emplacement. • L’emplacement doit se trouver à l’intérieur. • L’emplacement doit être exempt d’agents aéroportés et de toute autre substance contaminante. • La température de l’air doit être au moins de 4 °C (40 °F), mais ne doit pas excéder 43 °C (110 °F).
Section 2 Instructions d’installation Alimentation électrique COURANT ADMISSIBLE DE CIRCUIT TOTAL GÉNÉRALITÉS Le courant admissible de circuit total permet de sélectionner la dimension de câble de l’alimentation électrique. ! Avertissement Tout le câblage doit être conforme aux codes locaux, régionaux et nationaux.
Instructions d’installation Section 2 Service d’eau/Évacuations d’eau RACCORDEMENTS D’ÉVACUATION ALIMENTATION EN EAU Suivre ces directives lors de l’installation des conduites d’évacuation pour empêcher l’eau de retourner s’écouler dans la machine à glaçons et dans le bac de stockage : En fonction des conditions d’eau locales, il peut s’avérer nécessaire de traiter l’eau pour empêcher la formation de tartre, filtrer les sédiments, éliminer le chlore et améliorer le goût et la clarté.
Section 2 Instructions d’installation Dimensionnement/Raccordement des conduites d’alimentation en eau et d’évacuation ! Attention La tuyauterie doit être conforme aux codes locaux et régionaux. Emplacement Température de l’eau Pression d’eau Raccordement de la machine à glaçons Arrivée d’eau pour la fabrication de glaçons Arrivée d’eau de condenseur 4 °C (40 °F) Min. 32 °C (90 °F) Max. 137,9 kPA (20 psi) Min. 551,5 kPA (80 psi) Max.
Instructions d’installation Section 2 Avant la mise en marche de la machine à glaçons Toutes les machines à glaçons Manitowoc sont mises en route et ajustées en usine avant l’expédition. Normalement, les nouvelles installations ne requièrent aucun ajustement. Pour garantir un bon fonctionnement, suivre les Contrôles opérationnels figurant à la Section 3 du présent manuel.
Section 3 Fonctionnement Séquence de fabrication des glaçons SÉQUENCE DE DÉMOULAGE MISE EN MARCHE INITIALE OU MISE EN MARCHE APRÈS ARRÊT AUTOMATIQUE 5. Démoulage 1. Équilibrage de pression Avant le démarrage du compresseur, le robinet de gaz chaud est sous tension pendant 15 secondes pour équilibrer les pressions pendant la mise en marche initiale du système de réfrigération. 2.
Fonctionnement Section 3 Tableau de pièces sous tension RELAIS DE TABLEAU DE COMMANDE 1 2 3 POMPE À ROBINET BOBINE DE EAU DE GAZ RELAIS CHAUD MISE EN MARCHE INITIALE/MISE EN MARCHE APRÈS ARRÊT AUTOMATIQUE : 1. Équilibrage de pression 2. Mise en marche du système de réfrigération SÉQUENCE DE CONGÉLATION : 3. Prérefroidissement 4. Congélation SÉQUENCE DE DÉMOULAGE : 5. Démoulage ARRÊT AUTOMATIQUE : 6.
Section 3 Fonctionnement Vérifications opérationnelles CONTRÔLE DU ROBINET À FLOTTEUR D’EAU GÉNÉRALITÉS Avant que l’eau ne s’écoule dans le bac à eau, l’arrêt du robinet à flotteur doit être en position OPEN (OUVERTE). Cette machine à glaçons Manitowoc a été mise en route et ajustée en usine avant l’expédition. Normalement, une machine à glaçons nouvellement installée ne requiert pas d’être ajustée.
Fonctionnement Section 3 CONTRÔLE DU NIVEAU D’EAU CONTRÔLE DE L’ÉPAISSEUR DU PONT DE GLACE Contrôler le niveau d’eau pendant que la machine à glaçons se trouve en mode ICE et que la pompe à eau fonctionne. Le niveau d’eau correct se trouve entre 6,3 mm (1/4 po) et 9,5 mm (3/8 po) sous le haut du tuyau d’alimentation vertical. Un trait dans le bac à eau indique le niveau correct. La sonde d’épaisseur des glaçons est réglée en usine pour maintenir l’épaisseur du pont de glace à 3,2 mm (1/8 po).
Section 4 Entretien Nettoyage et désinfection intérieurs ! Attention GÉNÉRALITÉS Nettoyer et désinfecter la machine à glaçons tous les six mois pour un fonctionnement efficace. Si la machine à glaçons requiert un nettoyage et une désinfection plus fréquents, contacter une entreprise de maintenance qualifiée pour tester la qualité de l’eau et recommander un traitement approprié de l’eau. La machine à glaçons doit être démontée pour le nettoyage et la désinfection.
Entretien Section 4 C. Retirer la pompe à eau • Débrancher le cordon d’alimentation de la pompe à eau. Quand Utilisée SUPPRIMER THUMBSCREWS ET L'EAU POMPER PARCOURIR Nettoyage de la sonde d’épaisseur de glaçons • Mélanger une solution de nettoyant pour machines à glaçons Manitowoc et d’eau (60 ml [2 onces] de nettoyant pour 500 ml [16 onces] d’eau) dans un récipient. • Tremper la sonde d’épaisseur de glaçons pendant au moins 10 minutes.
Section 4 Entretien Démontage Démontage • Tourner les deux extrémités du tube interne jusqu’à ce que les languettes soient alignées avec les rainures. • Faire pivoter l’extrémité cannelée jusqu’à ce que la languette s’aligne sur la clavette. • Tirer l’extrémité du tube interne vers l’extérieur. • Tirer les extrémités du tube interne vers l’extérieur.
Entretien Section 4 • Déconnecter le tube d’arrivée d’eau du robinet à flotteur au niveau du raccord de compression. • Retirer le bouchon et l’écran filtrant pour nettoyage. G. Retrait du bac à eau • Appliquer une pression vers le bas sur le tube-siphon et retirer du fond du bac à eau. • Retirer la vis papillon supérieure. • Tout en supportant le bac à eau, retirer les deux vis papillon de dessous le bac à eau. • Retirer le bac à eau de la zone du bac.
Section 4 Entretien I. Retrait de la porte du bac • Saisir l’arrière de la porte du bac et pousser la porte du bac vers l’avant de 127 mm (5 po) environ. • Faire glisser la porte de bac vers l’arrière tout en appliquant une pression vers le haut (les goupilles de porte arrière glisseront dans la saignée et glisseront vers l’arrière jusqu’à la languette d’arrêt).
Entretien Section 4 Étape 12 Utiliser la moitié de la solution désinfectant/ eau pour désinfecter toutes les surfaces de zone alimentaire de la machine à glaçons et du bac. Utiliser un chiffon ou une éponge pour appliquer abondamment la solution. Lors de la désinfection, faire particulièrement attention aux zones suivantes : Étape 20 Utiliser la moitié de la solution désinfectant/ eau pour désinfecter toutes les surfaces de zone alimentaire de la machine à glaçons et du bac.
Section 4 Entretien Inspection de la machine à glaçons Nettoyage du condenseur Vérifier tous les raccords et conduites d’eau pour fuites éventuelles. S’assurer également que la tuyauterie de réfrigération ne frotte pas ou ne vibre pas contre d’autres tubes, panneaux, etc.
Section 5 Service clientèle Liste de vérification En cas de problème pendant le fonctionnement de la machine à glaçons, suivre la liste de vérification ci-dessous avant de contacter le service technique. Les réglages périodiques et procédures d’entretien ne sont pas couverts par la garantie. Problème La machine glaçons ne fonctionne pas. La machine glaçons s’arrte et peut tre remise en marche en déplaçant l’interrupteur bascule sur OFF puis sur ICE.
Section 5 Problme La machine glaçons produit des glaçons creux et incomplets, ou le motif de remplissage de glaçons sur l’évaporateur est incomplet. Service clientèle Cause possible La sonde d’épaisseur des glaçons est déréglée. Le niveau du bac eau est trop élevé ou trop bas. La crépine du robinet flotteur d’eau est sale. La filtration de l’eau est médiocre. Eau d’arrivée chaude. Le robinet flotteur d’eau ne fonctionne pas. Pression d’eau entrante incorrecte. Faible capacité de glaçons.
Service clientèle Section 5 Garantie commerciale de la machine à glaçons Manitowoc Ice, Inc.
Section 5 Service clientèle Garantie limitée résidentielle de la machine à glaçons CE QUE COUVRE LA PRÉSENTE GARANTIE LIMITÉE Sous réserve des exclusions et limitations ci-dessous, Manitowoc Foodservice (« Manitowoc ») garantit au client d’origine toute nouvelle machine à glaçons fabriquée par Manitowoc (le « Produit ») contre tout défaut de matériau ou vice de fabrication pendant la période de garantie décrite ci-dessous dans des conditions normales d’utilisation et d’entretien, et suite à une installati
© 2010 Manitowoc Continuing product improvements may necessitate change of specifications without notice. Part Number 040002380 9/12 Manitowoc Manitowoc Foodservice 2110 South 26th Street, P.O. Box 1720 Manitowoc, WI 54221-1720, USA Ph: 920-682-0161 Fax: 920-683-7589 Visit us online at: www.manitowocice.