Service manual
6-5
Section 6
Service
Condenser Fan Motor Replacement
Access to remove, clean or replace the condenser
fan/motor can be obtained by performing the
following:
1. Disconnect electrical power to the ice machine
at the electrical service disconnect.
2. Remove the screws that secure the condenser to
the cabinet and the base to the cabinet.
3. Slide the base forward until contact is made
with the stop screw (approximately 2.5" 6.3cm).
CAUTION
Do not move base past the stop screw, tubing
damage could result.
4. Remove right hand screw securing condenser to
base.
5. Pivot condenser forward to obtain 5" between
the cabinet and condenser shroud. Take care not
to kink refrigeration tubing.
REMOVE THREE
SCREWS AND PULL
BASE FORWARD TO
STOP SCREW.
2.5" (6.3CM) TO
STOP SCREW
REMOVE SCREW AND PIVOT
CONDENSER TO OBTAIN
5"(12.7CM) CLEARANCE
BETWEEN CABINET AND
CONDENSER SHROUD.
5" (12.7CM)
CLEARANCE AFTER
PIVOTING CONDENSER
PT1295A