Service manual

3-3
Section 3 Ice Machine Operation
Q130/Q210/Q270 SELF-CONTAINED ICE MACHINES
ENERGIZED PARTS CHART
ICE MAKING SEQUENCE OF OPERATION
CONTROL BOARD RELAYS RELAY
1233A3B
LENGTH
WATER PUMP HOT GAS VALVE RELAY COIL
COMPRESSOR
CONDENSER
FAN MOTOR
of “ON”
TIME
INITIAL START-UP/
START UP AFTER
AUTO SHUT-OFF:
1. Pressure
Equalization
OFF ON OFF OFF OFF
15
Seconds
2. Refrigeration
System Start-up
OFF ON ON ON ON
5
Seconds
FREEZE
SEQUENCE:
3. Pre-Chill
OFF OFF ON ON ON
30
Seconds
4. Freeze
ON OFF ON ON ON
Until 7 sec.
water contact
with ice
thickness
probe
HARVEST
SEQUENCE:
5. Harvest
OFF
ON ON ON ON
Bin switch
activation
AUTOMATIC
SHUT-OFF:
6. Auto Shut-Off
OFF OFF OFF OFF OFF
Until
bin switch
re-closes
Condenser Fan Motor: The fan motor is wired through a fan cycle pressure control, therefore, it may cycle on and off.